Abstract

V diplomski nalogi je prikazan izračun standardne požarne odpornosti prostoležečih lesenih nosilcev skladno s standardom SIST EN 1995-1-2:2005 - Evrokod 5: Projektiranje lesenih konstrukcij - 1-2. del: Splošna pravila - Projektiranje požarnovarnih konstrukcij. Standard podaja dve poenostavljeni metodi za izračun požarne odpornosti elementov. V nalogi je predstavljena metoda z zmanjšanim prečnim prerezom. Analizirani so stropni nosilci s konstantnim prečnim prerezom iz masivnega in lepljenega lameliranega lesa ter ravni dvokapni strešni nosilec iz lepljenega lameliranega lesa. Poleg računskih kontrol požarne odpornosti so prikazane tudi računske kontrole v mejnem stanju nosilnosti in mejnem stanju uporabnosti v običajnih pogojih, ki so izvedene skladno s standardom SIST EN 1995-1-1:2005 - Evrokod 5: Projektiranje lesenih konstrukcij - 1-1. del: Splošna pravila in pravila za stavbe. Izkaže se, da je požarna odpornost lesenih nosilcev relativno velika (> R60), kar je posledica dejstva, da je za dimenzioniranje nosilcev merodajna kontrola v mejnem stanju uporabnosti.

Keywords

gradbeništvo;diplomska naloga;leseni nosilec;lameliran les;požarna odpornost;poenostavljena metoda;Evrokod 5;

Data

Language: Slovenian
Year of publishing:
Typology: 2.11 - Undergraduate Thesis
Organization: UL FGG - Faculty of Civil and Geodetic Engineering
Publisher: [Živa Pavšič]
UDC: 614.8:624.011.1(043.2)
COBISS: 8082273 Link will open in a new window
Views: 1090
Downloads: 522
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

Secondary language: English
Secondary title: Calculation of standard fire resistance of glued laminated timber beams
Secondary abstract: In this graduation thesis the calculation of standard fire resistance of a simple single span timber beam is presented. The calculation is executed in accordance with EN 1995-1-2:2005 - Eurocode 5: Design of timber structures - Part 1-2: General - Structural fire design. Standard gives two simplified methods for determining fire resistance, the thesis is focused on reduced cross section method. Fire resistance is determined for floor beams with constant cross-section, made from solid timber and from glued laminated timber, and also for glued laminated timber roof beam with variable cross-section. Design of beams for ultimate and serviceability limit state is also executed in accordance with EN 1995-1-1:2005 - Design of timber structures - Part 1-1: General - Common rules and rules for buildings. On the basis of presented study it can be concluded that the fire resistance of timber beams is relatively high (> R60) which is a consequence of serviceability limit state being relevant for the ambient design of the beams.
Secondary keywords: civil engineering;graduation thesis;timber beam;glued laminated timber;fire resistance;simplified method;Eurocode 5;
Type (COBISS): Bachelor thesis/paper
Study programme: 0
Embargo end date (OpenAIRE): 1970-01-01
Thesis comment: Univ. v Ljubljani, Fak. za gradbeništvo in geodezijo
Pages: XIV, 37 str.
ID: 10841352