magistrsko delo magistrskega študijskega programa II. stopnje Strojništvo
Abstract
Namen naloge je zasnova, izdelava in testiranje lastne merilne postaje za meritve dihanja tal. Za namen boljše prostorske pokritosti meritev dihanja tal bo zasnovana naprava vsebovala različne avtomatizirane aktuatorske sklope. V nalogi smo prikazali možnost izdelave lastnega nedisperzivnega infrardečega (NDIR) merilnega zaznavala, predstaviti omejitve in izbrati ustrezno alternativo. Za aktuatorski sklop, izsledki o porabi električne energije pokažejo, da je potrebna ponovna presoja izbranih aktuatorjev. Izvedene meritve s komercialno alternativo NDIR zaznavala so pokazale, da je za časovni niz surovih podatkov koncentracij CO2, podatke za tok CO2 iz tal moč enostavno določiti, a bi za avtomatsko izračunavanje potrebovali bolj sofisticiran algoritem. Prikazan je tudi proces daljinskega pošiljanja podatkov s pomočjo GPRS modula na FTP strežnik.
Keywords
magistrske naloge;dihanje tal;ogljikov dioksid;nedisperzivna infrardeča merilna zaznavala;dinamična metoda zaprtih komor;linearni aktuatorji;modul GPRS;FTP server;
Data
Language: |
Slovenian |
Year of publishing: |
2019 |
Typology: |
2.09 - Master's Thesis |
Organization: |
UL FS - Faculty of Mechanical Engineering |
Publisher: |
[A. Pleško] |
UDC: |
681.122:631.433.3(043.2) |
COBISS: |
16658459
|
Views: |
881 |
Downloads: |
192 |
Average score: |
0 (0 votes) |
Metadata: |
|
Other data
Secondary language: |
English |
Secondary title: |
Avtonomous robotic measuring station for soil CO2 flux capture |
Secondary abstract: |
The goal of this thesis is to design, construct and test our own measuring station for measuring soil respiration. For the purpose of spreading measurements in the spatial domain the designed device will contain various automated actuator subassemblies. In addition the purpose of the task is to demonstrate the ability to develop our own nondispersive (NDIR) sensor, present its limitations and choose appropriate alternative. Results related to electrical current consumption of the actuator part of measuring station show that the choice of actuators should be reevaluated. Conducted measurements with a commercial alternative to the NDIR sensor showe that for the time series of raw CO2 concentrations, the data for CO2 soil flux can be easily calculated, but automatic calculation would require a more sophisticated algorithm. The process of remote sending of data via the GPRS module to the FTP server is also shown. |
Secondary keywords: |
soil respiration;carbon dioxide;NDIR sensor;closed dynamic chamber metod;linear actuators;GPRS module;FTP server; |
Type (COBISS): |
Master's thesis/paper |
Study programme: |
0 |
Embargo end date (OpenAIRE): |
1970-01-01 |
Thesis comment: |
Univ. Ljubljana, Fak. za strojništvo |
Pages: |
XXVI, 83 str. |
ID: |
11149326 |