magistrsko delo
Abstract
Tematika magistrske naloge je razvoj in implementacija nadzornega sistema za izvajanje varnostnih testov stroja. Predstavljena je pot, kako priti do frekvence omenjenega izvajanja testov. Varnost strojev je v osnovi predpisana s standardom ISO 12100, ki daje generalne smernice za njihovo oblikovanje. Uporablja se tudi standard ISO 13849, ki predstavlja splošna načela za načrtovanje in validacijo varnostnih delov krmilnih sistemov. V delu je podrobno analiziran ta standard, saj poda smernice funkcionalne varnosti strojev, kar zajema tudi dodatna varnostna načela, med katera spada varnostni preizkus. Nadzorni sistem se izvaja z dvema PLC-jema, povezanima s HMI aplikacijo. V drugem delu sta opisana program in vizualizacija, ki služita za spremljanje varnostne opreme in izvajanje varnostnih testov stroja.
Keywords
PLC;HMI;varnost strojev;standardi;funkcionalna varnost;varnostni test;magistrske naloge;
Data
Language: |
Slovenian |
Year of publishing: |
2019 |
Typology: |
2.09 - Master's Thesis |
Organization: |
UM FERI - Faculty of Electrical Engineering and Computer Science |
Publisher: |
[J. Žolger] |
UDC: |
620.1.051:681.518.52(043.2) |
COBISS: |
22774806
|
Views: |
536 |
Downloads: |
140 |
Average score: |
0 (0 votes) |
Metadata: |
|
Other data
Secondary language: |
English |
Secondary title: |
Control system for the implementation of machinery safety tests |
Secondary abstract: |
The topic of this master’s dissertation is the development and implementation of the control system of machinery safety tests. Its purpose is to present the process of reaching the frequency of its implementation. The safety of the machinery starts with the ISO 12100 standard which provides general guidelines for the designing of the machinery. Then the standard ISO 13849 comes into consideration which represents general principles for the design and validation of the safety components of control systems. This standard is analyzed in detail, because it provides the guidelines for the functional safety of the machinery among which are additional safety principles that also incorporate a safety test. The supervisory system is executed with two PLCs connected to the HMI application. In the second part there are the description of the program and the visualization that serve the monitoring of safety equipment and the execution of the supervisory system of machinery security tests. |
Secondary keywords: |
PLC;HMI;machine safety;standards;functional safety;safety test; |
Type (COBISS): |
Master's thesis/paper |
Thesis comment: |
Univ. v Mariboru, Fak. za elektrotehniko, računalništvo in informatiko, Mehatronika |
Pages: |
X, 96 f. |
ID: |
11213350 |