Abstract
Vsak pribor ima definirano neko mejo napake, znotraj tega intervala pa naj bi bil želen odmerjen volumen. V sklopu diplomske naloge smo preverjali merilno negotovost, pravilnost in natančnost posameznega volumetričnega pribora s statističnimi testi. V primerjavo smo vzeli polnilne pipete, birete, birete s kroglico, volumetrične steklenice in batne pipete. Pred eksperimentom smo pričakovali, da bo v splošnem najožje območje razširjene merilne negotovosti pri odmerjanju volumna z batno pipeto, največje pa bo pri odmerjanju volumna z volumetričnimi steklenicami. Ugotovili smo, da je območje razširjene merilne negotovosti močno odvisno od tega, kateri volumen smo odmerjali. V splošnem pa velja, da so za odmerjanje majhnih volumnov (do 1 mL) najbolj primerne batne pipete. Za odmerjanje večjih volumnov pa je bila najbolj primerna polnilna pipeta.
Keywords
steklen volumetrični pribor;batne pipete;merilna negotovost;pravilnost;natančnost;točnost;diplomska dela;
Data
Language: |
Slovenian |
Year of publishing: |
2019 |
Typology: |
2.11 - Undergraduate Thesis |
Organization: |
UL FKKT - Faculty of Chemistry and Chemical Technology |
Publisher: |
[K. Gaber] |
UDC: |
543.24(043.2) |
COBISS: |
1538416579
|
Views: |
924 |
Downloads: |
246 |
Average score: |
0 (0 votes) |
Metadata: |
|
Other data
Secondary language: |
English |
Secondary abstract: |
Every volumetric instrument has its own error limit and within this area should be the desired volume. In diploma experiments we checked measurement uncertainty, trueness and precision of individual volumetric instrument with statistical tests. In comparison we took volumetric pipettes, burettes, burettes with bead stopcock, volumetric flasks and piston pipettes. Before the experiment we expected, the narrowest area of expanded measurement uncertainty with piston pipettes and the widest one with volumetric flasks. We found out that the area of expanded measurement uncertainty is strongly dependent on the measured volume. In general, we can say that for measurement of small volume (up to 1 mL) piston pipette is the most appropriate. For measurement of larger volume, the volumetric pipette is the most appropriate. |
Secondary keywords: |
volumetric instruments;measurement uncertainty;trueness;precision;accuracy; |
Type (COBISS): |
Bachelor thesis/paper |
Study programme: |
1000373 |
Embargo end date (OpenAIRE): |
1970-01-01 |
Thesis comment: |
Univ. v Ljubljani, Fak. za kemijo in kemijsko tehnologijo, UNI Kemija |
Pages: |
42 str. |
ID: |
11363447 |