Polona Palma (Author), Barbara Sušec (Author), Urška Puh (Author)

Abstract

Uvod: Okvarjena propriocepcija skočnega sklepa povzroča nestabilnost in motnje ravnotežja. Občutek za položaj sklepa pomeni zavedanje položaja sklepa v prostoru med mirovanjem. Namen raziskave je bil ugotoviti zanesljivost posameznega preiskovalca pri merjenju občutka za položaj zgornjega skočnega sklepa pri zdravih mladih preiskovancih. Metode: Sodelovalo je 30 zdravih preiskovancev, v povprečju starih 20,7 ± 1,5 leta. Z elektrogoniometrom (Biometrics SG 110) je bil v razmiku sedmih dni dvakrat izmerjen občutek za položaj zgornjega skočnega sklepa v treh testnih kotih. Iz absolutnih napak je bil izračunan intraklasni koeficient korelacije (ICC) ter 95-odstotni interval zaupanja. Rezultati: Za merjenje občutka za položaj zgornjega skočnega sklepa pri kotu 40º plantarne fleksije smo ugotovili zmerno zanesljivost (povprečje: ICC = 0,52; zadnje 3 sekunde: ICC = 0,54). Pri testnem kotu 10° dorzalne fleksije kot tudi pri 25° plantarne fleksije je bila zanesljivost nizka (ICC ≤ 0,4). Zaključki: Zanesljivost posameznega preiskovalca pri merjenju občutka za položaj zgornjega skočnega sklepa z elektrogoniometrom po opisanem postopku je zmerna oziroma nizka. Poleg drugih izboljšav bi bilo smiselno spremeniti postopek, da bi omogočili večjo zbranost preiskovancev.

Keywords

fizioterapija;ocenjevanje;zanesljivost;propriocepcija;elektrogoniometer;

Data

Language: Slovenian
Year of publishing:
Typology: 1.01 - Original Scientific Article
Organization: UL ZF - University College of Health Studies
UDC: 615.8:303.094.5
COBISS: 5570155 Link will open in a new window
ISSN: 1318-2102
Views: 508
Downloads: 95
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

Secondary language: English
Secondary title: Intratester reliability of the talocrural joint position sense measurement with electrogoniometer
Secondary abstract: Background: Impaired proprioception of the talocrural joint causes its instability and decreased balance. Joint position sense is perception of the body segments positions in space during rest. Purpose of the study was to evaluate intra-rater reliability for measurement of the talocrural joint position sense in healthy young subjects. Methods: 30 healthy subjects aged on average 20.7 ± 1.5 years participated in the study. The talocrural joint position sense in three test angles was tested twice in seven-day interval using electrogoniometer (Biometrics SG110). On the basis of absolute errors, the intraclass correlation coefficient (ICC) and 95% confidence interval were calculated. Results: Reliability of the talocrural joint position sense at 40° of plantarflexion was moderate (average: ICC = 0.52; last 3 seconds: ICC = 0.54). Reliability of assessment at 10° degrees of dorsiflexion and at 25° of plantarflexion was low (ICC ≤ 0.4). Conclusions: Intra-rater reliability for measurement of the talocrural joint position sense using electrogoniometer with described procedure is moderate or low. Among other improvements, changes of the procedure to increase of subjects’ concentration would be reasonable.
Secondary keywords: physiotherapy;assessment;reliability;proprioception;electrogoniometer;
Pages: str. 10-17
Volume: ǂLetn. ǂ26
Issue: ǂšt. ǂ2
Chronology: dec. 2018
ID: 11423690