zanesljivost posameznega preiskovalca pri ocenjevanju zdravih mladih odraslih
Abstract
Uvod: Test stoje na eni nogi je enostaven klinični test za ocenjevanje ravnotežja, ki ima več različic. Od testnih pogojev (podlaga, vidni priliv) je odvisno, kaj povedo rezultati. Namen raziskave je bil preveriti zanesljivost posameznega preiskovalca za izvedbo testa stoje na eni nogi po natančno opisanem postopku v štirih pogojih pri zdravih mladih odraslih. Metode: Sodelovalo je 36 zdravih preiskovancev, starih od 18 do 30 let. Dvakrat, v razmiku sedmih dni, so opravili test stoje na eni nogi po načelu modificiranega kliničnega testa senzorične interakcije. Za vsak testni pogoj so bili z ANOVA analizirani najboljše vrednosti in povprečni časi med prvim in drugim merilnim dnem ter izračunani ICC. Rezultati: Za bolj zanesljive rezultate so se izkazale najboljše vrednosti. Na trdi podlagi z odprtimi očmi so vsi preiskovanci dosegli najdaljši čas testa. Na trdi podlagi z zaprtimi očmi je bil ICC 0,64, na mehki podlagi z odprtimi očmi 0,67, na mehki podlagi z zaprtimi očmi pa 0,33. Zaključki: Zanesljivost posameznega preiskovalca za test stoje na eni nogi na trdi podlagi z zaprtimi očmi in na mehki podlagi z odprtimi očmi je pri mladih zdravih odraslih dobra.
Keywords
ravnotežje;test stoje na eni nogi;mehka podlaga;zanesljivost posameznika;
Data
Language: |
Slovenian |
Year of publishing: |
2015 |
Typology: |
1.01 - Original Scientific Article |
Organization: |
UL ZF - University College of Health Studies |
UDC: |
615.8:796.012.266 |
COBISS: |
4885355
|
ISSN: |
1318-2102 |
Views: |
529 |
Downloads: |
178 |
Average score: |
0 (0 votes) |
Metadata: |
|
Other data
Secondary language: |
English |
Secondary title: |
Single-leg stance test according to the principle of clinical test of sensory interaction and balance |
Secondary abstract: |
Introduction: Single-leg stance test is a simple clinical test for balance assessment, which exists in many versions. The testing conditions (support-surface, visual input) imply the mining of results. Purpose: Purpose of the study was to establish the intra-ratter reliability of certain procedure of a single-leg stance test in healthy young adults. Methods: 36 healthy subjects, aged 18–30 years, performed single-leg stance test according to the principle of clinical test of sensory interaction and balance. Test was repeated after 7 days. Per each test condition, maximal and average values between first and second measurement day were analysed with ANOVA, and ICC was calculated. Results: The results expressed with maximal values were more reliable. On firm surface with eyes open, everyone reached maximal test time. On firm surface with eyes closed, the ICC was 0.49, on compliant surface with eyes open, 0.67, and on compliant surface with eyes closed, 0.33. Conclusion: The intra-ratter reliability of a single-leg stance test on firm surface with eyes closed and on compliant surface with eyes open in assessment of young healthy adults is good. |
Secondary keywords: |
balance;one-leg stance test;compliant surface;intra-ratter reliability; |
URN: |
URN:NBN:SI |
Pages: |
str. 30-40 |
Volume: |
ǂLetn. ǂ23 |
Issue: |
ǂšt. ǂ1 |
Chronology: |
jun. 2015 |
ID: |