Andrea Cuesta-Mosquera (Author), Griša Močnik (Author), Luka Drinovec (Author), Thomas Müller (Author), Sascha Pfeifer (Author), Maria Cruz Minguillon (Author), Björn Briel (Author), Paul Buckley (Author), Vadimas Dudoitis (Author), Javier Fernández-García (Author)

Abstract

Aerosolized black carbon is monitored worldwide to quantify its impact on air quality and climate. Given its importance, measurements of black carbon mass concentrations must be conducted with instruments operating in quality-checked and ensured conditions to generate data which are reliable and comparable temporally and geographically. In this study, we report the results from the largest characterization and intercomparison of filter-based absorption photometers, the Aethalometer model AE33, belonging to several European monitoring networks. Under controlled laboratory conditions, a total of 23 instruments measured mass concentrations of black carbon from three well-characterized aerosol sources: synthetic soot, nigrosin particles, and ambient air from the urban background of Leipzig, Germany. The objective was to investigate the individual performance of the instruments and their comparability; we analyzed the response of the instruments to the different aerosol sources and the impact caused by the use of obsolete filter materials and the application of maintenance activities. Differences in the instrument-to-instrument variabilities from equivalent black carbon (eBC) concentrations reported at 880 nm were determined before maintenance activities (for soot measurements, average deviation from total least square regression was −2.0 % and the range −16 % to 7 %; for nigrosin measurements, average deviation was 0.4 % and the range −15 % to 17 %), and after they were carried out (for soot measurements, average deviation was −1.0 % and the range −14 % to 8 %; for nigrosin measurements, the average deviation was 0.5 % and the range −12 % to 15 %). The deviations are in most of the cases explained by the type of filter material employed by the instruments, the total particle load on the filter, and the flow calibration. The results of this intercomparison activity show that relatively small unit-to-unit variability of AE33-based particle light absorbing measurements is possible with well-maintained instruments. It is crucial to follow the guidelines for maintenance activities and the use of the proper filter tape in the AE33 to ensure high quality and comparable black carbon (BC) measurements among international observational networks.

Keywords

black carbon;aerosol;absorption;filter absorption photometer;aethaloemter;

Data

Language: English
Year of publishing:
Typology: 1.01 - Original Scientific Article
Organization: UNG - University of Nova Gorica
UDC: 504
COBISS: 61521411 Link will open in a new window
ISSN: 1867-1381
Views: 1364
Downloads: 0
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

URN: URN:SI:UNG
Pages: str. 3195-3216
Volume: ǂVol. ǂ14
Issue: ǂiss. ǂ4
Chronology: 2021
DOI: 10.5194/amt-14-3195-2021
ID: 12852160
Recommended works:
, how smart can the cities be?
, instrument inter-comparison and results of source and source-component modelling
, harmonised source apportionment of organic aerosol using 22 year-long ACSM/AMS datasets