diplomsko delo
Marcel Tišler (Author), Nataša Gros (Mentor)

Abstract

V diplomskem delu smo preverili merilno negotovost pri izbranih volumetričnih napravah in dejavnike, ki vplivajo na posamezno vrsto redčenja. Predstavili smo razlike med vrstami redčenja ter pojasnili potek do izračuna združene merilne negotovosti. V eksperimentalnem delu smo nato ugotavljali ponovljivost polnjenja volumetričnih priborov (bučke, polnilne pipete in batne pipete) s tehtanjem. Na podlagi eksperimentalnih rezultatov smo izračunali združene merilne negotovosti faktorja redčenja za oba primera redčenja. Ugotovili smo, da se območje merilne negotovosti faktorja redčenja pri redčenju na volumen pri posamezni volumetrični steklenici z večanjem volumna pipete zmanjšuje. Pri redčenju raztopine z volumnom se merilna negotovost faktorja redčenja z večanjem volumna dodatka s pipeto povečuje. Pri tem je največji vpliv na merilno negotovost imela ponovljivost polnjenja, kjer je tudi prišlo do manjših odstopanj. Paziti moramo, da polnimo čim bolj ponovljivo, uporabljamo čist in neokrušen pribor in delamo pri konstantnih pogojih (temperatura, tlak), da dobimo rezultate v določenem območju, saj vse te komponente vplivajo na merilno negotovost.

Keywords

merilna negotovost;ponovljivost;volumen;faktor redčenja;volumetrični pribor;redčenje na volumen;redčenje z volumnom;diplomska dela;

Data

Language: Slovenian
Year of publishing:
Typology: 2.11 - Undergraduate Thesis
Organization: UL FKKT - Faculty of Chemistry and Chemical Technology
Publisher: [M. Tišler]
UDC: 543.24(043.2)
COBISS: 135072515 Link will open in a new window
Views: 38
Downloads: 7
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

Secondary language: English
Secondary title: Measurement uncertainty in dilution of solution to volume or with volume
Secondary abstract: In the diploma work, we evaluated the measurement uncertainty of selected volumetric instruments and the factors that influence each type of dilution. We presented the differences between the types of dilution an explained the process of calculating the combined measurement uncertainty. In the experimental part, we determined the repeatability of filling volumetric instruments (flasks, volumetric pipettes, and piston pipettes) by weighing. Based on the experimental results, we calculated the combined measurement uncertainties of the dilution factor for both cases of dilution. We found that the value of measurement uncertainty of the dilution factor when diluting solution to volume for an individual volumetric flask decreases with increasing volume of the pipette, while when diluting solution with volume it increases with increasing volume of the pipette addition. The greatest influence on the measurement uncertainty was due to repeatability of filling, where there were also minor deviations. We must be careful to fill as repeatably as possible, use clean and uncontaminated instruments and work under constant conditions (temperature, pressure) to obtain results in a certain range, as all these components affect the measurement uncertainty.
Secondary keywords: measurement uncertainty;repeatability;volume;dilution factor;volumetric instruments;Univerzitetna in visokošolska dela;
Type (COBISS): Bachelor thesis/paper
Study programme: 1000373
Embargo end date (OpenAIRE): 1970-01-01
Thesis comment: Univ. v Ljubljani, Fak. za kemijo in kemijsko tehnologijo, UNI Kemija
Pages: 34 str.