diplomsko delo
Jaka Malovrh (Author), Boštjan Blažič (Mentor)

Abstract

Diplomsko delo opisuje postopek revizije razdelilne transformatorske postaje. Ta se osredotoča na natančen pregled in analizo ključnih komponent postaje. Opisano je tudi kaj vse spada pod vzdrževanje elektroenergetskih sistemov, ki vključuje redne preglede, preventivne ukrepe, popravila in posodobitve opreme, kar je ključno za podaljševanje življenjske dobe sistema in preprečevanja nepredvidenih okvar. Za primer sem si izbral RTP Škofja Loka. Revizija, ki je bila izvedena po nedavni rekonstrukciji RTP, je obsegala celovit pregled stikališč, transformatorjev in zaščitnih sistemov, s ciljem zagotoviti optimalno delovanje in zanesljivost elektroenergetskega omrežja. V nalogi sem se posebej posvetil primerjavi dveh vrst stikalnih celic, ki sta bili analizirani glede na njune tehnične lastnosti, zanesljivost, vzdržljivost in primernost za specifične obratovalne pogoje. Primerjava je pokazala ključne razlike med celicama, kar ima pomemben vpliv na izbiro opreme za RTP.

Keywords

razdelilna transformatorska postaja;revizija;primerjava;vzdrževanje;univerzitetni študij;Aplikativna elektrotehnika;diplomske naloge;

Data

Language: Slovenian
Year of publishing:
Typology: 2.11 - Undergraduate Thesis
Organization: UL FE - Faculty of Electrical Engineering
Publisher: [J. Malovrh]
UDC: 004:621.3(043.2)
COBISS: 220717827 Link will open in a new window
Views: 115
Downloads: 27
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

Secondary language: English
Secondary title: HV/MV substation condition audit
Secondary abstract: The thesis describes the procedures of revision of a substation. This focuses on a precise examination and analasis of the key components of the station. It is also described what all falls under maintanance of electroenergetic systems, which include regular check ups, preventive measures, reparations and equipment updates, which are all crucial for extending the lifetime of the system and preventing unexpected malfunctions. For an example I chose Substation Škofja Loka. The revision, which was carried out after the recent reconstruction of the substation, consisted of a complete examination of switchyards, transformers and protection systems, with the goal to ensure optimal operation and reliability of the electroenergetic system. In the thesis I especially concentrated on the comparison of two switchgear cells, which were analysed based on their technical characteristics, reliability, endurance and suitability for specific operation conditions. The comparison showed the key differences between the two cells, which has an important influence on the choice of the substation equipment.
Secondary keywords: substation;revision;comparison;maintanance;
Type (COBISS): Bachelor thesis/paper
Study programme: 1000315
Thesis comment: Univ. v Ljubljani, Fak. za elektrotehniko
Pages: 1 spletni vir (1 datoteka PDF (IX, 70 str.))
ID: 25389313
Recommended works:
, no subtitle data available
, diplomska naloga visokošolskega strokovnega programa
, diplomska naloga visokošolskega strokovnega študijskega programa