diplomsko delo
Zoran Verhovšek (Author), Andrej Orgulan (Mentor)

Abstract

Diplomska naloga v prvem delu zajema osnoven opis zahtev za modeliranje industrijske razsvetljave, teoretično ozadje standardno uporabljenih svetlobno tehničnih komponent, opis cirkadijskega ritma in vpliv ter posledice, ki ga ima nanj svetloba. V drugem delu je prikazano obstoječe stanje razsvetljave v proizvodnji hali podjetja Gorenja d.d. Ob ugotovitvi o neustreznih rezultatih je nato izveden pregled možnosti izboljšave obstoječe razsvetljave. Zaradi energetske neučinkovitosti zastarelih svetilk je ugotovljeno, da je investicija v kakršnokoli dodatno opremo nesmiselna. Nato je prikazana rešitev z novo prilagojeno in učinkovitejšo razsvetljavo. Sledi primerjava rezultatov obeh vrst razsvetljave ter zaključek z anketo o zadovoljstvu delavcev z obstoječo razsvetljavo v dveh proizvodnih halah.

Keywords

industrijska razsvetljava;energetsko učinkovita razsvetljava;svetloba;standard SIST EN 12464-1;

Data

Language: Slovenian
Year of publishing:
Typology: 2.11 - Undergraduate Thesis
Organization: UM FERI - Faculty of Electrical Engineering and Computer Science
Publisher: [Z. Verhovšek]
UDC: 621.327:628.976/.977(043.2)
COBISS: 18436886 Link will open in a new window
Views: 1608
Downloads: 223
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

Secondary language: English
Secondary title: ENERGY EFFICIENCY ANALYSIS OF INDUSTRIAL LIGHTING OF WORK PLACES IN GORENJE COMPANY
Secondary abstract: The thesis in the first part covers the basic description and requirements that need to be fulfilled when planning industrial lighting from scratch. It also covers the theoretical background of standard luminares that are used in industrial facilities, circadian rhythms and the impact of lighting on it.The second part of the thesis presents the existing lighting in the production hall PPA2 in the company Gorenje d.d. The given unsuitable finding required a closer analysis to see if it’s possible to make a sufficient upgrade of the existing lighting. The aged luminaires were the reason that there are no real benefits from upgrading existing lighting systemthat would be worth the investment. The first part of the thesis provides a solution with a new, build from scratch lighting, which would provide the required illumination and efficiency. The final part of the thesis focuses on a survey about worker satisfaction regarding the lighting in two production halls.
Secondary keywords: industrial lighting;energy-efficient lighting;standard SIST EN 12464-1;
URN: URN:SI:UM:
Type (COBISS): Bachelor thesis/paper
Thesis comment: Univ. v Mariboru, Fak. za elektrotehniko, računalništvo in informatiko
Pages: IX, 57 f.
ID: 8730432