diplomska naloga
Abstract
V diplomski nalogi obravnavam sprijemnost med jekleno armaturno palico premera 12 mm in
različnimi vrstami betonov. Standard Evrokod 2 in modelni predpis FIB Model Code 2010
določata mejno sprijemno napetost, ki je modelirana kot strižna napetost po obodu palice.
Standarda v povezavi s to tematiko ne obravnavata vlaknastih betonov. Skopo je tudi
področje betonov visoke trdnosti. V ta namen smo izvedli raziskavo z izvlečnim oziroma
»pull-out« testom. Pri delu smo se opirali na standard SIST EN 10080:2005, ki opredeljuje
potek raziskave kot tudi obliko preizkušancev. Med izvlečnim testom se palico, ki je vgrajena
v betonsko kocko, izvleče iz betonskega objema. V raziskavi smo preizkusili beton normalne
trdnosti, beton visoke trdnosti in visoko trden vlaknast beton z 1 % jeklenih vlaken glede na
prostornino betona. Za vsako vrsto betona smo izdelali tri preizkušance. Rezultati so
pokazali, da se preizkušanci iz betona visoke trdnosti obnašajo podobno kot preizkušanci iz
običajnega betona, vendar pri tem dosegajo trikrat boljšo sprijemnost.
Keywords
gradbeništvo;diplomska dela;sprijemna napetost;izvlečni test;beton visoke trdnosti;vlaknast beton;Evrokod;FIB Model Code 2010;
Data
Language: |
Slovenian |
Year of publishing: |
2015 |
Typology: |
2.11 - Undergraduate Thesis |
Organization: |
UL FGG - Faculty of Civil and Geodetic Engineering |
Publisher: |
[A. Dežman] |
UDC: |
624.012.45(497.4)(043.2) |
COBISS: |
7254625
|
Views: |
3082 |
Downloads: |
679 |
Average score: |
0 (0 votes) |
Metadata: |
|
Other data
Secondary language: |
English |
Secondary title: |
Bond between concrete and reinforcing steel |
Secondary abstract: |
This thesis researches bond characteristics between the 12mm steel reinforcing bar and
various types of concrete. Standard Eurocode 2 and FIB Model Code 2010 define ultimate
bond stress, which acts like shear stress around the reinforcing bar. In correlation with bond,
high strength concrete is poorly represented, furthermore, research and information on fibre
concrete are lacking. Therefore, a series of pull-out tests, based on standard SIST EN
10080:2005, have been conducted. In this study, behaviours of normal strength concrete,
high-strength concrete and high-strength steel fibre-reinforced concrete with 1 % of steel
fibres have been tested. Three pull-out tests were carried out for each type of concrete. The
results show that high-strength concrete acts in similar way as normal strength concrete.
However, its ultimate bond stress was three times larger. |
Secondary keywords: |
civil engineering;graduation thesis;bond stress;pull-out test;high strength concrete;tefibre concrete;Eurocode;FIB Model Code 2010; |
File type: |
application/pdf |
Type (COBISS): |
Bachelor thesis/paper |
Thesis comment: |
Univ. v Ljubljani, Fak. za gradbeništvo in geodezijo |
Pages: |
X, 36 str. |
ID: |
9056494 |