Povzetek
Namen diplomske naloge je določitev celotnega ali raztopljenega organskega ogljika v bazenskih vodah. Gre za širitev matrice, saj so z enako metodo, na enak način ter na enakih aparatih, merili TOC že za ostale vrste vod (pitne vode, površinske vode, podzemne vode, odpadne vode, izlužke, mineralne vode).
Analizna metoda je obsegala optimizacijo metode, pripravo umeritvene premice, ugotavljanje stabilnosti sistema, ugotavljanje pravilnosti linearnega modela umeritvene premice, koeficienta kvalitete, ponovljivost in obnovljivost v bazenskih vodah, pri čemer smo dobili podatke za celoten validacijski postopek.
Vsebnosti organskega ogljika v bazenskih vodah smo statistično ovrednotili glede na zahteve validacijskega postopka. Rezultati ponovljivosti in obnovljivosti so na štirih različnih koncentracijskih nivojih sprejemljivi in so znotraj predpisanega kriterija (20%).
Metodo smo preizkusili tudi z analizami in primerjavami certificiranih referenčnih materialov in v različnih medlaboratorijskih primerjavah, kjer je bilo odstopanje naših meritev v povprečju 4%.
Potrdili smo, da izbrana analizna metoda izpolnjuje predpisane pogoje ter zagotavlja pravilnost in zanesljivost rezultatov.
Ključne besede
bazenske vode;validacija analizne metode;oksidacijski katalizatorji;oksidacija;
Podatki
Jezik: |
Slovenski jezik |
Leto izida: |
2011 |
Izvor: |
Maribor |
Tipologija: |
2.11 - Diplomsko delo |
Organizacija: |
UM FKKT - Fakulteta za kemijo in kemijsko tehnologijo |
Založnik: |
[T. Hohler] |
UDK: |
543.2/.9:628.166(043.2) |
COBISS: |
16040726
|
Št. ogledov: |
2324 |
Št. prenosov: |
306 |
Ocena: |
0 (0 glasov) |
Metapodatki: |
|
Ostali podatki
Sekundarni jezik: |
Angleški jezik |
Sekundarni naslov: |
Determination of total organic carbon and dissolved organic carbon in swimmingpool waters |
Sekundarni povzetek: |
The purpose of diploma thesis is to measure the total or dissolved organic carbon in swimming pool waters. Thus the matrix will be extended, since the same method, the same procedure and the same technical equipment was already used for measuring TOC in other water types, e.g., drinking water, surface waters, underground waters, waste waters, leachates, mineral waters).
The analytical method includes method optimisation, preparing calibration curve, assessing system stability, assessing accuracy of the linear model of calibration curve, quality coefficient, repeatability and reproducibility in swimming pool waters, where we acquired the data for the entire validation procedure.
The content of organic carbon in swimming pool waters was statistically evaluated according to the requirements of the validation procedure. The results of repeatability and reproducibility are acceptable at four different concentration levels and meet the criterion prescribed (20%).
The method was tested in the analyses of certified reference materials and in various inter-laboratory comparisons. We stayed within the tolerance limit of 4%.
We have confirmed that the analytical method in question complies with the conditions prescribed and ensures the accuracy and reliability of the results. |
Sekundarne ključne besede: |
TOC;swimming pool water;NDIR detector;method validation;oxidation catalyst;oxidation; |
URN: |
URN:SI:UM: |
Vrsta dela (COBISS): |
Diplomsko delo |
Komentar na gradivo: |
Univ. v Mariboru, Fak. za kemijo in kemijsko tehnologijo |
Strani: |
XIV, 74 f. |
Ključne besede (UDK): |
mathematics;natural sciences;naravoslovne vede;matematika;chemistry;crystallography;mineralogy;kemija;analytical chemistry;analizna kemija;chemical methods of analysis;applied sciences;medicine;technology;uporabne znanosti;medicina;tehnika;engineering;technology in general;inženirstvo;tehnologija na splošno;public health engineering;water;sanitation;illuminating engineering;sanitarna tehnika;zdravstvena tehnika;voda;sanitarne naprave;svetlobna tehnika;water supply;water treatment;water consumption;oskrba z vodo;priprava vode;uporaba vode; |
ID: |
1016423 |