diplomsko delo univerzitetnega študijskega programa
Povzetek
Rutenijevi kompleksi so daleč najbolj razširjeni O2 indikatorji, ker imajo učinkovito luminescenco, relativno stabilen kovina – ligand prenos naboja vzbujenega stanja, hiter odzivni čas, močno vidno absorpcijo, velike Stokes – ove preskoke in visoko fotokemično stabilnost.
V diplomski nalogi smo za izdelavo senzorjev uporabili različne koncentracije rutenijevega kompleksa v različnih topilih. Preizkusili smo različne PVC folije uporabljene kot nosilec. Na »Spin – coaterju« smo optimirali program s katerim smo dobili optično gledano najbolj homogene nanose senzorskih raztopin. Senzorje smo izpostavili različnim koncentracijam kisika. Linearnost smo preverili v območju od 0 do 100 % koncentracije kisika. Ugotovili smo linearnost za senzorje pripravljene iz 60 in 80 mg rutenijevega kompleksa.
»Spin – coating« se je izkazal kot alternativna metoda za nanos senzorskih raztopin, vendar po celotni senzorski površini ni možno pripraviti homogenega nanosa, kar smo pokazali tudi z opravljenimi SEM posnetki. Za nanašanje senzorskih raztopin na nosilec bi v bodoče uporabili mehanski nanos z natančnim nožem.
Ključne besede
optični kemijski senzorji;senzorji za določanje kisika;Rutinijevi kompleksi;
Podatki
Jezik: |
Slovenski jezik |
Leto izida: |
2012 |
Izvor: |
Maribor |
Tipologija: |
2.11 - Diplomsko delo |
Organizacija: |
UM FKKT - Fakulteta za kemijo in kemijsko tehnologijo |
Založnik: |
[M. Kelc] |
UDK: |
544.165(043.2) |
COBISS: |
16693270
|
Št. ogledov: |
1984 |
Št. prenosov: |
198 |
Ocena: |
0 (0 glasov) |
Metapodatki: |
|
Ostali podatki
Sekundarni jezik: |
Angleški jezik |
Sekundarni naslov: |
Development and characterization of optical Ru - sensors for oxygen determination |
Sekundarni povzetek: |
Ruthenium complexes are by far the most widely used O2 indicators due to their efficient luminescence, relatively long − life metal − tolerant charge transfer when in the excited state, fast response time, strong visible absorption, large Stokes shifts, and high photochemical stability.
In this thesis, we used different concentrations of ruthenium complexes in various solvents for sensor production. We used various PVC foils as the carrier. On »Spin – coater«, we optimized the program which helped us get optically most homogeneous sensor coating solutions. The sensors were exposed to various concentrations of oxygen. The linearity was tested in the range from 0 % to 100 % of oxygen concentration. We determined the linearity of sensors which were prepared from 60 to 80 mg of ruthenium complex.
To conclude, "Spin − coating" could be an alternative method for the application of sensor solutions, but it is not possible to prepare the homogeneous layer on the whole sensor surface, which was demonstrated via implemented SEM recordings. In the future, it would be better to apply the sensor solutions to the carrier mechanically using the high precision knife. |
Sekundarne ključne besede: |
optical chemical sensors;sensors for oxygen determination;Ruthenium complexes; |
URN: |
URN:SI:UM: |
Vrsta dela (COBISS): |
Diplomsko delo |
Komentar na gradivo: |
Univ. v Mariboru, Fak. za kemijo in kemijsko tehnologijo |
Strani: |
XIII, 50 f. |
Ključne besede (UDK): |
mathematics;natural sciences;naravoslovne vede;matematika;chemistry;crystallography;mineralogy;kemija;physical chemistry;fizikalna kemija;chemical structure of matter;kemijska struktura snovi; |
ID: |
1026078 |