Povzetek

Namen zaključnega projekta je numerična analiza vrtinčnih tokov v kovinskih delih skoznjih izolatorjev. Analiza je izvedena na osnovi metod končnih elementov v programskem orodju EleFAnT3D. Osredotočili smo se na kovinsko mrežico, ki je sestavni del večine skoznjih izolatorjev in služi za razporeditev potencialov ter polja v notranjosti in v okolici izolatorja. Na osnovi analize vrtinčnih tokov smo v teh kovinskih delih izračunali izgubno moč, kar bi nadalje omogočalo analizo joulskih izgub in segrevanja skoznjega izolatorja. Opravljene so primerjave rezultatov med različnimi debelinami kovinske mrežice, različnimi razmerji med zračno režo ter kovinskim materialom in različnimi vrednostmi električnega toka skozi vodnike.

Ključne besede

vrtinčni tok;skoznji izolatorji;izgubna moč;metoda končnih elementov;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UM FERI - Fakulteta za elektrotehniko, računalništvo in informatiko
Založnik: [V. Jelenc]
UDK: 621.3
COBISS: 22112790 Povezava se bo odprla v novem oknu
Št. ogledov: 556
Št. prenosov: 64
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Analysis of eddy currents in metal parts of bushing insulators
Sekundarni povzetek: The purpose of the project is the numerical analysis of eddy currents occurant in the metal portions of bushing insulators. The analysis is based on the finite element method and was performed in the EleFAnT 3D program, with which the measurements were performed. The main focus of the research were the metal meshes, which are a component of the majority of bushing insulators and serve to allocate the electrical potential inside and in the surroundings of the insulator. The results of the analysis were then used to calculate the dissipation of power within the metal components, which would further allow the analysis and calculation of Joul – losses and heating of the bushing insulator. A results comparison was performed between various thicknesses of metal meshes, different air slot ratios and metal materials as well as between various intensities of electrical current through conductors.
Sekundarne ključne besede: eddy current;bushing insulator;power dissipation;finite element method;
URN: URN:SI:UM:
Vrsta dela (COBISS): Delo diplomskega projekta/projektno delo
Komentar na gradivo: Univ. v Mariboru, Fak. za elektrotehniko, računalništvo in informatiko, Elektrotehnika
Strani: IX, 37 f.
ID: 10957379
Priporočena dela:
, diplomska naloga univerzitetnega študijskega programa
, diplomsko delo univerzitetnega študijskega programa
, diplomsko delo univerzitetnega študijskega programa