diplomsko delo
Patricija Janežič (Avtor), Sonja Hlebš (Recenzent), Miroljub Jakovljević (Mentor)

Povzetek

Uvod: Najpogostejši način merjenja gibljivosti sklepov so goniometrične meritve. Meritve izvajamo navadno z univerzalnim goniometrom. Izvajamo jih z namenom pridobivanja objektivnih meritev o gibljivosti posameznega sklepa. Ker meritve običajno izvajajo različni terapevti, je pomembna zanesljivost posameznega preiskovalca. Namen: Namen diplomskega dela je bil ugotoviti ponovljivost in zanesljivost pasivnih goniometričnih meritev obsega gibljivosti kolenskega sklepa. Metode dela: V raziskavo je bilo vključenih 30 zdravih preiskovank starih med 18 in 25 let. Merjenja so potekala v dveh sejah s 48 urnim vmesnim premorom. Razlike med meritvami smo vrednotili z analizo variance za ponovljene meritve (p≤0,05), če je bila razlika med meritvami pomembna smo opravili Bonferroni »post hoc« test (p≤0,05). Ponovljivost in zanesljivost smo vrednotili z intraklasnim koeficientom korelacije (ICC 2,1). Izračunali smo tudi najmanjšo dejansko razliko. Za obdelavo podatkov smo uporabili statistični program MedCalc Statistical Software version 14.12.0 (MedCalc Software bvba, Ostend, Belgium) Microsoft Excel (verzija 2013, Microsoft Corporation, Redmond, ZDA). Rezultati: Tako v prvi, kot v drugi seji med zaprednimi meritvami začetnega in končnega položaja ni bilo pomembnih razlik. Ponovljivost testa, je bila visoka. Najvišji ICC smo izračunali pri meritvah ekstenzije (ICC = 0,935), najnižjega pa pri prvih meritvah fleksije (ICC = 0,808) v prvi sejii. Povprečne vrednosti meritev med prvo in drugo sejo so se pomembno ralikovale le pri meritvah ekstenzije (p=0,013). Vrednosti ICC so bile za vse zmerjene spremenljivke nad 0,8, kar kaže na odlično zanesljivost metode. Zanesljivost je bila boljša pri meritvahfleksij (ICC = 0,925). Najmanjša dejanska razlika je bila pri meritvah ekstenzije 4,3̊, pri meritvah fleksije 4,0̊ in za celoten obseg giba 6,0̊. Razprava in zaključek: Goniometrične meritve kolenskega sklepa so ponovljive in zanesljive, nekoliko bolj pri meritvah fleksije kot pri merjenju pasivnega giba ekstenzije kolenskega sklepa. Zanesljivost je primerljiva z drugimi, že izvedenimi raziskavami. Najmanjša zaznana sprememba je prav tako kaže na odlično zanesljivost. V primerjavi z že izvedenimi raziskavami, je najmanjša zaznana sprememba v naši raziskavi še manjša.

Ključne besede

diplomska dela;fizioterapija;goniometrične meritve;zanesljivost preiskovalcev;pasivna sklepna gibljivost;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UL ZF - Zdravstvena fakulteta
Založnik: [P. Janežič]
UDK: 615.8
COBISS: 5571947 Povezava se bo odprla v novem oknu
Št. ogledov: 1200
Št. prenosov: 446
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Repeatibility [!] and reliability of knee passive range of motion goniometric measurements
Sekundarni povzetek: Introduction: The most common way of measuring joint mobility is goniometric measurements. Measurements are performed with a universal goniometer. We carry them out in order to obtain objective measurements of the flexibility of a particular joint. Because measurements are usually conducted by different therapists, the intratester reliability is very important. Purpose: The purpose of the diploma thesis was to identify the repeatability and reliability of passive goniometric measurements of the range of flexibility of the knee joint. Methods: The study involved 30 healthy subjects aged between 18 and 25 years. Measurements were made in two sessions with a 48 hours intermittent break. The differences between the measurements were assessed by the analysis of the variance for repeated measurements (p≤0.05), if the difference between the measurements was significant, we performed the "post hoc" test of Bonferroni (p≤0.05). Repeatability and reliability were assessed by the intraclassic correlation coefficient (ICC 2.1). We also calculated the lowest real difference. MedCalc Statistical Software version 14.12.0 (MedCalc Software bvba, Ostend, Belgium) and Microsoft Excel (version 2013, Microsoft Corporation, Redmond, USA) was used to process data. Results: Thus, in the first, as in the second session, there were no significant differences between the initial measurements of the initial and final positions. The repeatability of the test was high. The highest ICC was calculated for extensions measurements (ICC = 0.935) and the lowest in the first measurements of flexion (ICC = 0.808) in the first session. The average values of measurements between the first and frugo sessions were important only for extensions measurements (p = 0.013). ICC values for all measured variables above 0.8, indicating the excellent reliability of the method. Reliability was better in the measurement of fleshes (ICC = 0.925). The slightest actual difference was in the measurements of the extension of 4.3°, in the measurements of the flexion 4.0° and for the entire range of movement 6.0°. Discussion and conclusion: Goniometric measurements of the knee joint are repeatable and reliable, somewhat more in the measurement of flexion than in the measurement of the passive motion of the knee joint extension. Reliability is comparable to other studies already carried out. The smallest detected change also indicates excellent reliability. Compared to already performed studies, the smallest reliable change in our study is even lower.
Sekundarne ključne besede: diploma theses;physiotherapy;goniometric measurements;intratester reliability;passive joint mobility;
Vrsta dela (COBISS): Diplomsko delo/naloga
Študijski program: 0
Komentar na gradivo: Univ. v Ljubljani, Zdravstvena fak., Oddelek za fizioterapijo
Strani: 22 str.
ID: 10994222