magistrsko delo magistrskega študijskega programa II. stopnje Strojništvo
Luka Boneš (Avtor), Drago Bračun (Mentor)

Povzetek

V podjetju je bilo potrebno izdelati čistilno napravo za čiščenje odpadnih industrijskih vod, ki bo zagotavljala, da prečiščene vode ustrezajo kriterijem za izpust v kanalizacijsko omrežje. Najpomembnejši parameter, ki ga mora sistem zagotoviti je ph raztopine. Poleg ph-ja je potrebno meriti volumen in pretok raztopine skozi cisterno, ki sem ga meril z ultra zvočnim senzorjem. Glavna kriterija pri izbiri komponent sta bila zanesljivost in cena. Oddaljen nadzor in upravljanje sem izvedel preko Blynk platforme. V testnem obdobju se je izkazalo, da čistilna naprava zagotavlja primerno čisto odpadno vodo. Za znižanje števila zastojev pa je potrebno zamenjati tip pretočne črpalke.

Ključne besede

magistrske naloge;čistilne naprave;zasnova krmiljenja;SCADA nadzorni sistem;oddaljen nadzor;vizualizacija podatkov;industrijske odpadne vode;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.09 - Magistrsko delo
Organizacija: UL FS - Fakulteta za strojništvo
Založnik: [L. Boneš]
UDK: 621.398:628.32(043.2)
COBISS: 15977987 Povezava se bo odprla v novem oknu
Št. ogledov: 578
Št. prenosov: 209
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Design and implementation of the system for management and control of wastewater treatment plant
Sekundarni povzetek: The company had to build an industrial wastewater treatment plant to ensure that the treated water met the criteria for discharge into the sewerage system The most important parameter the system has to provide is the pH of the solution. In addition to the pH value, it is necessary to measure the volume and flow of the solution through the tank, for which I used an ultrasonic sensor. The main criteria for the selection of the components were reliability and price. We implemented remote control and management using the Blynk platform. During the trial period it was shown that the treatment plant provides sufficient clean treated water. However, to further improve the reliability of the system, the flow pump type must be replaced.
Sekundarne ključne besede: master thesis;wastewater treatment plant;design control;SCADA;remote control;data visualization;industrial wastewater;
Vrsta dela (COBISS): Magistrsko delo/naloga
Študijski program: 0
Konec prepovedi (OpenAIRE): 1970-01-01
Komentar na gradivo: Univ. Ljubljana, Fak. za strojništvo
Strani: XXII, 61 str.
ID: 11587490
Priporočena dela:
, magistrsko delo magistrskega študijskega programa II. stopnje Strojništvo
, diplomsko delo visokošolskega študijskega programa
, diplomsko delo visokošolskega strokovnega študijskega programa