diplomsko delo
Vita Slak (Avtor), Miroljub Jakovljević (Recenzent), Darja Rugelj (Mentor)

Povzetek

Uvod: Zmožnost prehajanja iz sedečega v stoječ položaj predstavlja bistven element telesne pripravljenosti. Zahteva precejšnjo mišično zmogljivost, velike obsege gibljivosti sklepov, primerno tehniko in ustrezno ravnotežje. Pri časovno merjenih testih vstajanja s stola se pogosto uporablja interval 30 sekund, v katerem preiskovanec izvede čim več pravilnih gibov vstajanja. Tako pridobimo podatke o posameznikovi mišični zmogljivosti spodnjih udov. Namen: Namen diplomskega dela je bil pregledati raziskave o merskih lastnostih testa vstajanja s stola v tridesetih sekundah pri različnih skupinah preiskovancev. Metode dela: Uporabljena je bila deskriptivna metoda s sistematičnim pregledom literature, ki je potekal v podatkovni zbirki PubMed in zajel raziskave o merskih lastnostih, ki so ustrezale merilom za vključitev. Iskanje literature je potekalo v slovenskem in angleškem jeziku. Zajete so bile raziskave, objavljene do konca novembra 2020. Rezultati: V pregled literature je bilo vključenih 13 raziskovalnih člankov. Zanesljivost so preverjali v desetih, veljavnost v osmih, sposobnost zaznavanja sprememb prav tako v desetih raziskavah. Rezultati zanesljivosti so pokazali, da je test vstajanja s stola v tridesetih sekundah visoko do odlično zanesljiv tako pri posameznem preiskovalcu (ICC = 0,84–0,97) kot tudi med preiskovalci (ICC = 0,92–0,98). Rezultati veljavnosti so raznoliki in večinoma nakazujejo zmerno povezanost s primerljivimi testi telesne pripravljenosti ali mišične zmogljivosti. Test dobro razlikuje med visoko in nizko telesno dejavnimi posamezniki ter negativno korelira s starostjo. Razprava in zaključek: Pregled literature je pokazal, da je test vstajanja s stola v 30 sekundah zanesljiva in veljavna metoda za ocenjevanje ter je njegova uporaba v kliničnem okolju primerna. Test ne zahteva veliko prostora, materiala ali časa. V raziskavah so se pojavljali različni protokoli izvedbe testa, ki bi jih bilo smiselno poenotiti. Za najbolj učinkovito ocenjevanje pacienta se priporoča kombinirati test vstajanja s stola v tridesetih sekundah z drugimi merami izida.

Ključne besede

diplomska dela;fizioterapija;mišična zmogljivost;prehod med položaji;zanesljivost;veljavnost;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UL ZF - Zdravstvena fakulteta
Založnik: [V. Slak]
UDK: 615.8
COBISS: 74915843 Povezava se bo odprla v novem oknu
Št. ogledov: 367
Št. prenosov: 68
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Measurement properties of 30-second sit-to-stand test
Sekundarni povzetek: Introduction: The ability to move from a sitting to a standing position is an essential element of physical fitness. It requires considerable muscle capacity, broad range of motion, proper technique and balance. In timed sit to stand tests, an interval of 30 seconds is often used, in which the subject performs as many correct movements of getting up as possible. Thus, we obtain data on an individual’s muscle strength of the lower extremities. Purpose: The purpose of this thesis was to review research on the measurement properties of the thirty second sit to stand test in various groups of subjects. Methods: A descriptive method with a systematic review of the literature was used fort his thesis. The literature review was conducted in the PubMed database and included research articles on measurement properties that met the inclusion criteria. The search for literature was limited to research articles in Slovenian and English language, published by the end of November 2020. Results: Thirteen studies were included in the literature review. Reliability was tested in ten, validity in eight, and ability to detect changes also in ten studies. The reliability results showed that the 30-second sit-to-stand test is highly to excellently reliable both for intrarater (ICC = 0.84–0.97) and interrater reliability (ICC = 0.92–0.98). Validity results are varied and mostly suggest a moderate association with comparable fitness or muscle performance tests. The 30-second sit to stand test distinguishes well between high and low physically active individuals and correlates negatively with age. Discussion and conclusion: A review of the literature has shown that the 30-second sit-to-stand test is a reliable and valid method of assessment and its use in a clinical setting is appropriate. The test does not require much space, material or time. It would make sense to unify test protocols because various different versions of this test were performed in the included studies. To capture a broader range of effects and for more effective assessment of the patient it is recommended to combine the 30-second sit-to-stand test with other assessment instruments or to include it in a battery of assessment tools.
Sekundarne ključne besede: diploma theses;physiotherapy;muscle strength;postural transition;reliability;validity;
Vrsta dela (COBISS): Diplomsko delo/naloga
Študijski program: 0
Konec prepovedi (OpenAIRE): 1970-01-01
Komentar na gradivo: Univ. v Ljubljani, Zdravstvena fak., Oddelek za fizioterapijo
Strani: 38 str.
ID: 13282189