Povzetek

Uvod: Intraaortna balonska črpalka (IABP) je bila uvedena v zgodnjih šestdesetih letih prejšnjega stoletja, z namenom zdravljenja hudih bolezni, npr. srčnega popuščanja in kardiogenega šoka. Še vedno je pogosta metoda zdravljenja nujnih bolezenskih stanj v enotah za intenzivno oskrbo. Metode: V zaključnem delu je bila uporabljena kvantitativna metodologija. Z eksperimentalnim delom smo izdelali simulacijski učni model intraaortne balonske črpalke. V magistrskem delu smo povprašali še naše sodelavce o tipičnih spremenljivkah na sami napravi. Rezultati: Rezultati so pokazali uspešno zdravljenje z IABP kot podpori srčni mišici. Z ugodnimi hemodinamskimi učinki izboljša kardio-cirkulatorno stanje pacienta. Znanje, ki smo ga preverili pri zaposlenih, nas ni prepričalo o tem, da imajo le-ti dovolj pridobljenih informacij in znanja za delo z IABP. Izdelali smo učni simulacijski model, ki bo služil za predstavitev in demonstracijo delovanja IABP. Razprava in sklep: Delo z IABP zahteva določena specifična znanja, saj ne gre za vsakdanjo uporabljeno metodo zdravljenja. Predlagamo dodatna izobraževanja na področju zdravljenja pacienta z IABP na simulacijskem modelu, ki smo ga tudi izdelali.

Ključne besede

IABP;mehanična podpora;srce;hemodinamika;simulation model;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.09 - Magistrsko delo
Organizacija: UM FZV - Fakulteta za zdravstvene vede
Založnik: [B. Tomanič]
UDK: 004.94:616.12(043.2)
COBISS: 85893891 Povezava se bo odprla v novem oknu
Št. ogledov: 302
Št. prenosov: 32
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Simulation model of an intraaortic balloon pump
Sekundarni povzetek: Introduction: The intraaortic balloon pump (IABP) was introduced in the early 1960s as a treatment for severe heart failure and cardiogenic shock. It is still a common method of treating emergencies in intensive care units. Methods: This master's thesis used quantitative methods to create an experimental simulation model of an intraaortic balloon pump. Further to this, it includes a section in which we inquired with our colleagues as to the typical variables of the device. Results: The results showed that treatment with IABP provided effective support to the heart muscle. Having favourable hemodynamic effects, it improved the cardio-circulatory function of the patient. However, the inquiry among colleagues failed to convince us that they had acquired enough information and expertise to use the IABP effectively. Thus, we created a learning simulation model that will serve to present and demonstrate the use of the IABP. Discussion and conclusion: The use of the IABP requires specific knowledge, as it is not an everyday used method of treatment. Based on our findings, we propose additional training for effective and efficient treatment of patients with IABP, utilizing the simulation model that we developed for this purpose.
Sekundarne ključne besede: IABP;mechanical circulatory support;heart;hemodynamic;simulation model;Computer Simulation;Heart Failure;Shock, cardiogenic;Računalniška simulacija;Srčno popuščanje;Kardiogeni šok;
Vrsta dela (COBISS): Magistrsko delo/naloga
Komentar na gradivo: Univ. v Mariboru, Fak. za zdravstvene vede