Povzetek

V zadnjih letih obstaja veliko zanimanje za uporabo sline v diagnostične namene. Zbiranje sline je v primerjavi s krvjo in urinom preprostejše in ne invazivno. Med elementi, ki jih lahko določamo v slini, je tudi jod. Jod ima v telesu pomembno vlogo, od njega je namreč odvisno delovanje ščitnice. Pomanjkanje joda je na svetu še vedno zelo razširjeno, zato je iskanje hitre in zanesljive metode za njegovo določanje aktualna tema. Za določanje joda v slini smo uporabili ICP-MS, saj omogoča hitro analizo velikega števila vzorcev in ima dovolj nizke meje določitve. Pred analizo vzorcev smo preverili tudi vpliv pH in matrice. Za določitev joda v vzorcih smo uporabili interni standard telur. Primerjali smo tudi dva tipa analizatorjev, ki se uporabljata pri ICP-MS, in sicer kvadrupolni in TOF analizator.

Ključne besede

slina;analiza sline;vloga joda v telesu;induktivno sklopljena plazma;ICP-MS;diplomska dela;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UL FKKT - Fakulteta za kemijo in kemijsko tehnologijo
Založnik: [H. M. Žibert]
UDK: 543.51:546.15(043.2)
COBISS: 164097027 Povezava se bo odprla v novem oknu
Št. ogledov: 10
Št. prenosov: 3
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Determination of Iodine in Saliva by ICP-MS
Sekundarni povzetek: There has been an increase of use of saliva as a diagnostic fluid in recent years. It offers many advantages compared to blood plasma and urine as it can be collected non-invasively and in a simple manner. One of the elements present in saliva is iodine. Iodine is needed for synthesis of thyroid hormones and the working of the thyroid gland. Iodine deficiency is still extremely common among our society, which is why many researchers are trying to find a better way of determining iodine levels in human bodies. We used inductively coupled plasma mass spectrometry (ICP-MS) to determine iodine concentrations in saliva samples. Before analyzing the samples, we tested the effects of pH and the sample matrix. We used the internal standard method for the determination of iodine in saliva samples. We also compared two types of analyzers used in ICP-MS, the quadrupole and TOF analyzer.
Sekundarne ključne besede: saliva analysis;iodine;inductively coupled plasma;mass spectrometry;Jod;Masna spektrometrija;Univerzitetna in visokošolska dela;
Vrsta dela (COBISS): Diplomsko delo/naloga
Študijski program: 1000373
Konec prepovedi (OpenAIRE): 1970-01-01
Komentar na gradivo: Univ. v Ljubljani, Fak. za kemijo in kemijsko tehnologijo, UNI Kemija
Strani: 39 str.