diplomska naloga
Povzetek
Namen diplomske naloge je ovrednotiti kakovost notranjega zraka (IAQ) v prenovljeni večstanovanjski stavbi v Ljubljani po metodi Level(s), ki je enotni okvir za trajnostno vrednotenje stavb v njihovem življenjskem ciklu in temelji na zakonodaji EU. Za potrebe raziskave smo se osredotočili na kazalnik 4.1. Kakovost notranjega zraka, s katerim smo preverili lastnosti stavbe po vselitvi (raven 3). Raziskava je razdeljena na pet sklopov: 1. preučitev okvira Level(s) (zakonodajno osnovo in prenos v prakso); 2. preučitev kazalnika 4.1. Kakovost notranjega zrak; 3. določitev metodologije za potrebe vrednotenja IAQ; 4. izvedba meritev izbranih parametrov IAQ na ravni 3 in ovrednotenje razreda IAQ; 5. nabor ukrepov za izboljšanje kakovosti zraka. Meritve koncentracij CO2 (CCO2) (od 1. 9. do 17. 10. 2023) in relativne vlažnosti zraka (RHa) ter temperature zraka (Ta) (od 1. 9. do 24. 9. 2023) smo izvedli v treh različnih prostorih stanovanja: spalnica - S, dnevna soba - DS in kuhinja - K. Skladno z metodologijo Level(s) in SIST EN 16798-1:2019 smo določili trajanje meritev (h) in delež v opazovanem obdobju (%), ko so notranje razmere dosegle kategorijo kakovosti notranjega okolja (I – IV). Ugotovili smo, da obstoječe prezračevanje ne zagotavlja razmer I kategorije v celotnem trajanju meritev. Največja odstopanja od priporočenih vrednosti I kategorije se pojavijo pri RHa (kategorija I: 40-60 %), kjer so izmerjene vrednosti nad priporočenimi v S 72 % opazovanega obdobja, v DS 75 % in v K 76 %. Pri CCO2 je bil najbolj problematičen prostor S, kjer so izmerjene vrednosti odstopale od priporočenih (kategorija I: < 800 ppm) v 34 % opazovanega obdobja. Ta odstopa od pripočenih vrednosti (kategorija I: 23,5-25,5 °C) še posebej v K, kjer 63 % opazovanega obdobja presega priporočene vrednosti. Obravnavano stanovanje ima vgrajeno tudi mehansko prezračevanje, zato smo preverili, kako na CCO2 vplivajo trije različni scenariji prezračevanja: 1. mehansko prezračevanje deluje z običajno jakostjo; 2. mehansko prezračevanje ne deluje; 3. mehansko prezračevanje deluje z višjo jakostjo. Pri 1. scenariju je bila CCO2 od 451 ppm do 1542 ppm (povprečje 831 ppm); pri 2. scenariju od 452 ppm do 1009 ppm (povprečje 742 ppm, ni bilo prisotnih stanovalcev) in pri 3. scenariju od 433 ppm do 1609 ppm (povprečje 731 ppm). V zaključku raziskave smo predlagali ukrepe za optimizacijo prezračevalne strategije za stanovanje.
Ključne besede
gradbeništvo;diplomske naloge;UNI;GR;B-GR;Level(s);trajnostna gradnja;kakovost notranjega zraka;prezračevanje;ogljikov dioksid;temperatura zraka;relativna vlažnost zraka;
Podatki
Jezik: |
Slovenski jezik |
Leto izida: |
2024 |
Tipologija: |
2.11 - Diplomsko delo |
Organizacija: |
UL FGG - Fakulteta za gradbeništvo in geodezijo |
Založnik: |
[T. Čižman] |
UDK: |
502.3:613.15:728.2(043.2) |
COBISS: |
191055875
|
Št. ogledov: |
58 |
Št. prenosov: |
29 |
Ocena: |
0 (0 glasov) |
Metapodatki: |
|
Ostali podatki
Sekundarni jezik: |
Angleški jezik |
Sekundarni naslov: |
Indicators of indoor air quality and cost-efficient solutions, according to the European framework for sustainable buildings Level(s) on the case of the renovation of multi-family building in Ljubljana |
Sekundarni povzetek: |
The purpose of the thesis is to evaluate the indoor air quality (IAQ) in a renovated multi-family building in Ljubljana using the Level(s) method, a unified framework for the sustainable assessment of buildings throughout their lifecycle, based on EU legislation. For the research, we focused on the indicator 4.1. Indoor Air Quality with which we assessed the building's properties after occupancy (level 3). The study is divided into five sections: 1. examination of Level(s) framework; 2. study of indicator 4.1. Indoor Air Quality; 3. establishment of a methodology for evaluating IAQ; 4. execution of measurements of selected IAQ parameters (level 3) and assessment of IAQ category; 5. a set of measures to improve IAQ. Measurements of CO2 concentrations (CCO2) (from September 1st to October 17th, 2023), relative humidity (RHa) and air temperature (Ta) (from September 1st to September 24th, 2023) were performed in three different rooms within the apartment: bedroom (S), living room (DS) and kitchen (K). Following the Level(s) methodology and SIST EN 16798-1:2019, we determined the duration of measurements (h) and the percentage of the observation period (%) during which indoor conditions met the indoor environmental quality categories (I – IV). The existing ventilation system did not consistently achieve category I conditions throughout the measurement period. The most significant deviations from recommended values for category I occurred in RHa (category I: 40-60 %), where measured values exceeded recommendations in S for 72 % of the observed period, DS for 75 % and K for 76 %. Regarding CCO2, the most problematic space was S, with measured values deviating from the recommended values (category I: < 800 ppm) for 34 % of the measurement period. Regarding Ta, the most significant deviations from recommended values (category I: 23.5-25.5 °C) were observed in K, where 63 % of the observed period exceeded recommended values. The apartment also had a mechanical ventilation system installed, so we examined how CCO2 was affected by three different ventilation scenarios: 1. normal intensity of mechanical ventilation; 2. mechanical ventilation not operating; 3. higher intensity of mechanical ventilation. In scenario 1, CCO2 ranged from 451 ppm to 1542 ppm (average 831 ppm); in scenario 2, it ranged from 452 ppm to 1009 ppm (average 742 ppm, with no occupants present), and in scenario 3, it ranged from 433 ppm to 1609 ppm (average 731 ppm). In conclusion, we proposed measures to optimize the ventilation strategy for the apartment. |
Sekundarne ključne besede: |
graduation thesis;civil engineering;indoor air quality;sustainable construction;ventilation;carbon dioxide;indoor air temperature;indoor relative humidity; |