Sekundarni naslov: | THE INFLUENCE OF FLOW VELOCITY AND CATHODIC PROTECTION ON WATER SCALE PRECIPITATION FROM MAGNETICALLY TREATED WATER |
Sekundarni povzetek: | The diploma work shows study of the chemical composition of scale, whose main component is calcium carbonate. It also covers the precipitation of calcium carbonate as a primary component of the scale and the issue of elimination of scale in the boilers. We tried to reduce the scale using permanent magnets in a so-called magnetic treatment of water. We carried out experiments at different flow rates of water through the boiler using the magnesium cathodic protection, and in parallel, without its presence. We found that in our flow rates, and the average temperature is no significant difference in the magnetically treated water and in the ordinary and that the magnesium cathodic protection is also not much affective to the amount of scale precipitation. |
Sekundarne ključne besede: | scale;aragonite;calcite;calcium carbonate;permanent magnets;cathodic protection;magnetic water treatment; |