od bloka 5 Termoelektrarne Šoštanj do RTP Podlog
Rok Menih (Avtor), Sebastijan Seme (Mentor), Miralem Hadžiselimović (Komentor)

Povzetek

Delo obravnava dinamični model elektroenergetskega sistema (EES) od bloka 5 Termoelektrarne Šoštanj do RTP Podlog. Podana je primerjava med realnimi in idealnimi modeli posameznih elementov EES. Rezultati kažejo, da je uporaba idealnih elementov v dinamičnem modelu EES smiselna. V programskem paketu MatLAB / Simulink je z modulom Powersys sestavljen model EES od bloka 5 do RTP Podlog. Izvedena je analiza delovanja modela ob okvarah, kot sta vklop obremenjenega sistema in trifazni kratki stik. Opravljena je primerjava simulacijskih rezultatov iz dinamičnega modela EES z meritvami opravljenimi na realnem sistemu bloka 5. Rezultati kažejo, da se z dinamičnim modelom lahko približamo realnemu sistemu EES.

Ključne besede

elektroenergetski sistemi;dinamični modeli;termoelektrarne;diplomske naloge;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UM FE - Fakulteta za energetiko
Založnik: [R. Menih]
UDK: 621.311.22:621.314.2.05(043.2)
COBISS: 1024189532 Povezava se bo odprla v novem oknu
Št. ogledov: 1880
Št. prenosov: 155
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Dynamic model of power system : from bloc 5 Thermal Power Plant Šoštanj to distribution transformer station Podlog
Sekundarni povzetek: This work deals with a dynamic model of an electric power system (EPS) from the unit 5 of the Šoštanj Thermal Power Plant (ŠTPP) to the distribution transformer station (DTS) Podlog. A comparison between real and ideal models of individual elements of EPS has been made. The results show that ideal models can be used in the dynamic model of a complete EPS. The dynamic model of EPS from the unit 5 ŠTPP to DTS Podlog was built in the program package MatLAB / Simulink, using module Powersys. An analysis of the dynamic model operation during failures, such as power loaded system and three phase short circuit, has been presented as well. Furthermore, a comparison between simulation results from the dynamic model of the EPS and the measurements measured on the real system of the unit 5 ŠTPP has been made. According to the results, the dynamic model can be drawn nearer to the real system of the EPS.
Sekundarne ključne besede: power system;dynamic model;MatLAB / Simulink;Thermal power plant Šoštanj;
URN: URN:SI:UM:
Vrsta dela (COBISS): Diplomsko delo/naloga
Komentar na gradivo: Univ. v Mariboru, Fakulteta za energetiko
Strani: XVI, 74 f.
ID: 8730317
Priporočena dela:
, od bloka 5 Termoelektrarne Šoštanj do RTP Podlog
, diplomska naloga visokošolskega študijskega programa
, ni podatka o podnaslovu