diplomsko delo
Janez Jelen (Author), Milan Marčič (Mentor), Jurij Avsec (Co-mentor)

Abstract

V diplomski nalogi sem najprej predstavil splošno delovanje toplotne črpalke. Na kratko so opisane vse najpomembnejše komponente posamezne toplotne črpalke. Prav tako so na kratko opisane tudi vsi tipi kompresorskih toplotnih črpalk. Kasneje sem predstavil tudi izračun grelnega števila po standardu EN 255 in po uredbi EHPA (European Heat Pump Association V nadaljevanju sem na podlagi testiranja posameznih zunanjih toplotnih prenosnikov za toplotno črpalko predstavil ugotovitve in posamezne izračune grelnega števila . Pri tem se je upoštevalo zanesljivo delovanje toplotne črpalke pri vseh pogojih testiranja in dovolj visoko grelno število toplotne črpalke. Namen diplomskega dela je torej predstaviti različne tipe toplotnih prenosnikov in vpliv toplotnega prenosnika na delovanje toplotne črpalke. Tako so v tej diplomski nalogi predstavljeni štirje toplotni prenosniki, ki so se testirali pod standardnimi pogoji testiranja. Na koncu je na podlagi dobljenih rezultatov, predvsem dobro grelno število toplotne črpalke in zanesljivega delovanja, bil izbran najprimernejši in najučinkovitejši zunanji toplotni prenosnik za toplotno črpalko.

Keywords

toplotna črpalka;toplotni prenosnik;grelno število;

Data

Language: Slovenian
Year of publishing:
Source: Maribor
Typology: 2.11 - Undergraduate Thesis
Organization: UM FS - Faculty of Mechanical Engineering
Publisher: [J. Jelen]
UDC: 621.57:536.7(043.2)
COBISS: 16505622 Link will open in a new window
Views: 2804
Downloads: 295
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

Secondary language: English
Secondary title: Optimization of air-water heat pump with an external heat exchanger
Secondary abstract: The diploma work starts with the presentation of the overall performance of a heat pump. All major components of the individual heat pumps and all types of compression heat pumps are briefly described and followed by the presentation of the COP calculation according to EN 255 and EHPA Regulation (European Heat Pump Association). Further on, findings and COP calculations tested on the basis of individual external heat exchangers for heat pump are presented. Reliable operation of heat pumps in all test conditions and sufficiently high heat pump COP were considered most important parameters. The purpose of the diploma work is therefore to present the different types of heat exchangers and the impact a heat exchanger has on a heat pump. Thus, the diploma work presents the four heat exchangers, which were tested under standard test conditions. Finally, the most appropriate and effective external heat exchanger for the heat pump was selected according to the obtained results, main criteria being high heat pump COP and reliable operation
Secondary keywords: heat pump;heat exchanger;coefficient of performance;
URN: URN:SI:UM:
Type (COBISS): Undergraduate thesis
Thesis comment: Univ. v Mariboru, Fak. za strojništvo
Pages: IX, 56 f.
Keywords (UDC): applied sciences;medicine;technology;uporabne znanosti;medicina;tehnika;engineering;technology in general;inženirstvo;tehnologija na splošno;mechanical engineering in general;nuclear technology;electrical engineering;machinery;strojništvo;pneumatic energy;machinery and tools;refrigeration;pnevmatska energija;stroji in orodja;ohlajevanje;mathematics;natural sciences;naravoslovne vede;matematika;physics;fizika;heat;thermodynamics;statistical physics;termodinamika;toplota;statistična fizika;thermodynamics;energetics;termodinamika;toplotna energija;
ID: 1015989
Recommended works:
, diplomsko delo univerzitetnega študijskega programa 1. stopnje
, diplomsko delo visokošolskega strokovnega študijskega programa Strojništvo
, diplomsko delo visokošolskega strokovnega študijskega programa Strojništvo