diplomsko delo
Janez Jelen (Avtor), Milan Marčič (Mentor), Jurij Avsec (Komentor)

Povzetek

V diplomski nalogi sem najprej predstavil splošno delovanje toplotne črpalke. Na kratko so opisane vse najpomembnejše komponente posamezne toplotne črpalke. Prav tako so na kratko opisane tudi vsi tipi kompresorskih toplotnih črpalk. Kasneje sem predstavil tudi izračun grelnega števila po standardu EN 255 in po uredbi EHPA (European Heat Pump Association V nadaljevanju sem na podlagi testiranja posameznih zunanjih toplotnih prenosnikov za toplotno črpalko predstavil ugotovitve in posamezne izračune grelnega števila . Pri tem se je upoštevalo zanesljivo delovanje toplotne črpalke pri vseh pogojih testiranja in dovolj visoko grelno število toplotne črpalke. Namen diplomskega dela je torej predstaviti različne tipe toplotnih prenosnikov in vpliv toplotnega prenosnika na delovanje toplotne črpalke. Tako so v tej diplomski nalogi predstavljeni štirje toplotni prenosniki, ki so se testirali pod standardnimi pogoji testiranja. Na koncu je na podlagi dobljenih rezultatov, predvsem dobro grelno število toplotne črpalke in zanesljivega delovanja, bil izbran najprimernejši in najučinkovitejši zunanji toplotni prenosnik za toplotno črpalko.

Ključne besede

toplotna črpalka;toplotni prenosnik;grelno število;

Podatki

Jezik: Slovenski jezik
Leto izida:
Izvor: Maribor
Tipologija: 2.11 - Diplomsko delo
Organizacija: UM FS - Fakulteta za strojništvo
Založnik: [J. Jelen]
UDK: 621.57:536.7(043.2)
COBISS: 16505622 Povezava se bo odprla v novem oknu
Št. ogledov: 2804
Št. prenosov: 295
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Optimization of air-water heat pump with an external heat exchanger
Sekundarni povzetek: The diploma work starts with the presentation of the overall performance of a heat pump. All major components of the individual heat pumps and all types of compression heat pumps are briefly described and followed by the presentation of the COP calculation according to EN 255 and EHPA Regulation (European Heat Pump Association). Further on, findings and COP calculations tested on the basis of individual external heat exchangers for heat pump are presented. Reliable operation of heat pumps in all test conditions and sufficiently high heat pump COP were considered most important parameters. The purpose of the diploma work is therefore to present the different types of heat exchangers and the impact a heat exchanger has on a heat pump. Thus, the diploma work presents the four heat exchangers, which were tested under standard test conditions. Finally, the most appropriate and effective external heat exchanger for the heat pump was selected according to the obtained results, main criteria being high heat pump COP and reliable operation
Sekundarne ključne besede: heat pump;heat exchanger;coefficient of performance;
URN: URN:SI:UM:
Vrsta dela (COBISS): Diplomsko delo
Komentar na gradivo: Univ. v Mariboru, Fak. za strojništvo
Strani: IX, 56 f.
Ključne besede (UDK): applied sciences;medicine;technology;uporabne znanosti;medicina;tehnika;engineering;technology in general;inženirstvo;tehnologija na splošno;mechanical engineering in general;nuclear technology;electrical engineering;machinery;strojništvo;pneumatic energy;machinery and tools;refrigeration;pnevmatska energija;stroji in orodja;ohlajevanje;mathematics;natural sciences;naravoslovne vede;matematika;physics;fizika;heat;thermodynamics;statistical physics;termodinamika;toplota;statistična fizika;thermodynamics;energetics;termodinamika;toplotna energija;
ID: 1015989
Priporočena dela:
, diplomsko delo univerzitetnega študijskega programa 1. stopnje
, diplomsko delo visokošolskega strokovnega študijskega programa Strojništvo
, diplomsko delo visokošolskega strokovnega študijskega programa Strojništvo