diplomsko delo
Amadej Murovec (Author), Mitja Kolar (Mentor)

Abstract

Namen diplomskega dela je bil določiti vsebnost izbranih kovin v koreninah medvrstnih križancev bezga. Pred izvedbo analiz na ICP/OES je bilo treba trdne vzorce pretvoriti v tekočo obliko, ki je primerna za analizo. To sem storil s kislinskimi razklopi vzorcev. Kislinski razklop vzorcev sem izvajal ob prisotnosti HNO3, H2SO4 in H2O2. Tako pripravljeni vzorci so bili razredčeni z 1% HNO3 in shranjeni v 50-mL viale. Sledila je analiza z ICP/OES in za primer magnezija tudi AAS. Pred začetkom merjenja kovin v vzorcih sem izvedel umeritveno krivuljo z uporabo ICP-večelementne standardne raztopine VI (Merck). Vzorcem sem iz umeritvenih krivulj določil koncentracije kovin, v primeru magnezija in kalija pa sem moral vzorce tudi razredčiti. Koncentracije kovin sem interpretiral in določil linearnost merilnega območja.

Keywords

analizna kemija;bezeg;kovine;kislinski razklopi;analizne metode;atomska absorpcijska spektroskopija;induktivno sklopljena plazma;emisijska optična spektroskopija;diplomske naloge;

Data

Language: Slovenian
Year of publishing:
Typology: 2.11 - Undergraduate Thesis
Organization: UL FKKT - Faculty of Chemistry and Chemical Technology
Publisher: [A. Murovec]
UDC: 543.42(043.2)
COBISS: 1538327235 Link will open in a new window
Views: 1000
Downloads: 205
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

Secondary language: English
Secondary abstract: The purpose of my thesis was to determine concentrations of certain metals in the roots of interconnected crosses of elderberry. Before the ICP/OES analysis, I had to convert solid samples into a liquid form suitable for analysis. I have done this using the acid digestion technique. For this technique I used HNO3, H2SO4 and H2O2. The samples thus prepared were diluted with 1 % HNO3 and were kept in 50 mL vials. The samples were ready for the ICP/OES analysis and in the case of magnesium the AAS analysis was used too. Before the analysis of the samples of elderberry roots I performed the calibration, using a multistandard solution VI (Merck). I have determined concentrations of metals in samples from the calibration curve. For magnesium and potassium, the dilution was needed. I have interpreted the concentrations of metals and determined the linearity of the measuring zone.
Secondary keywords: elderberry;metals;acid digestion;inductively coupled plasma;optical emission spectrometry;atomic absorption spectroscopy;
Type (COBISS): Bachelor thesis/paper
Study programme: 1000374
Embargo end date (OpenAIRE): 1970-01-01
Thesis comment: Univ. v Ljubljani, Fak. za kemijo in kemijsko tehnologijo, VSŠ Kemijska tehnologija
Pages: 51 str.