diplomsko delo
Abstract
Kovine v pivu imajo velik vpliv na kvaliteto, okus ter izgled piva; prav tako pa na potek
alkoholne fermentacije. V 6 različnih vzorcih piva sem določal vsebnost izbranih kovin
(baker, železo, mangan in cink). Vzorce sem pripravil tako, da sem jih prefiltriral oz.
pripravil samo s kislinskim mikrovalovnim razklopom. Kovine imajo v pivu vsebnost na
ravni sledov, zato klasične metode niso primerne za uporabo. Koncentracije sem zato
določal z atomsko absorpcijsko in optično emisijsko spektroskopijo s pomočjo
umeritvene krivulje. ICP-OES nam za razliko od AAS omogoča, da naenkrat določamo
več elementov v vzorcu. Vsebnosti kovin v vzorcih sem primerjal z rezultati drugih
raziskav, poleg tega pa sem primerjal tudi razlikovanje rezultatov pri obeh uporabljenih
metodah.
Keywords
atomska absorpcijska spektroskopija;AAS;induktivno sklopljena plazma;optična emisijska spektrometrija;ICP-OES;pivo;diplomska dela;
Data
Language: |
Slovenian |
Year of publishing: |
2023 |
Typology: |
2.11 - Undergraduate Thesis |
Organization: |
UL FKKT - Faculty of Chemistry and Chemical Technology |
Publisher: |
[M. Kržišnik] |
UDC: |
543.42:546.3(043.2) |
COBISS: |
144733699
|
Views: |
34 |
Downloads: |
16 |
Average score: |
0 (0 votes) |
Metadata: |
|
Other data
Secondary language: |
English |
Secondary title: |
Determination of selected metals in samples of beer with atomic absorption and optical emission spectrometry |
Secondary abstract: |
Metals in beer have a big influence on quality, taste and looks of the beer, and also on the
process of fermentation. Therefore, I determined the contents of selected metals in 6
different samples of beer (copper, iron, manganese, zinc). The samples were prepared by filtering or by acid microwave digestion. The metals in beer are present in traces,
consequently classical methods are not suitable for use. The concentrations were
determined by atomic absorption and optical emission spectroscopy with the use of
calibration curve. On the contrary to AAS, ICP-OES allows us to measure more elements
in a sample at once. Contents of metals in the samples were compared to results of other
researches. In addition, also difference of results in both methods was compared. |
Secondary keywords: |
atomic absorption spectroscopy;beer;inductively coupled plasma;metals;optical emission spectrometry;Spektroskopija;Kovine;Univerzitetna in visokošolska dela; |
Type (COBISS): |
Bachelor thesis/paper |
Study programme: |
1000373 |
Embargo end date (OpenAIRE): |
1970-01-01 |
Thesis comment: |
Univ. v Ljubljani, Fak. za kemijo in kemijsko tehnologijo, UNI Kemija |
Pages: |
VIII, 36 str. |
ID: |
18140242 |