Secondary language: |
English |
Secondary title: |
Combined RC and timber structure house - design case |
Secondary abstract: |
A tenement house with a complex architectural plan was designed, supported by the program
SAP 2000 version 8, to a seismic load according to EC8. Its supporting structure is made of a
combined system of reinforced concrete walls and timber crosswise glued KLH slabs, used in
stories and roofs like wall panels. The bearing system is specific considering the present
construction practice, which is why we used experimentally obtained mechanical properties of
KLH cyclically stressed timber structure systems capable of bearing the horizontal load. |
Secondary keywords: |
timber structures;experimental research;experimentally supported modeling;seismic analysis;design case |
File type: |
application/pdf |
Type (COBISS): |
Undergraduate thesis |
Thesis comment: |
Univ. Ljubljana, Fakulteta za gradbeništvo in geodezijo, Oddelek za gradbeništvo, Univerzitetni študij, Konstrukcijska smer |
Pages: |
XI, 87 str. |
Type (ePrints): |
thesis |
Title (ePrints): |
Combined RC and Timber Structure House – Design Case |
Keywords (ePrints): |
lesene konstrukcije;eksperimentalne preiskave;eksperimentalno podprto modeliranje;potresna obtežba;primer projektiranja |
Keywords (ePrints, secondary language): |
timber structures;experimental research;experimentally supported modeling;seismic analysis;design case |
Abstract (ePrints): |
Stanovanjsko hišo z zahtevno arhitekturno zasnovo smo projektirali s pomočjo programa SAP 2000 verzija 8 nonlinear na potresno obtežbo v skladu z zahtevami EC8. Nosilna konstrukcija je izdelana iz kombiniranega sistema armiranobetonskih sten in lesenih navzkrižno lepljenih masivnih KLH plošč, ki so uporabljene v nosilni konstrukciji kot stenski elementi ter za medetažno in strešno konstrukcijo. Nosilni sistem je specifičen glede na trenutno gradbeno prakso, zato smo v izračunu upoštevali mehanske karakteristike lesenega nosilnega sistema za prevzem vodoravnih sil, kot smo jih eksperimentalno določili z laboratorijskimi preiskavami KLH lesenih stenskih elementov pri ciklični vodoravni obtežbi. |
Abstract (ePrints, secondary language): |
A tenement house with a complex architectural plan was designed, supported by the program
SAP 2000 version 8, to a seismic load according to EC8. Its supporting structure is made of a
combined system of reinforced concrete walls and timber crosswise glued KLH slabs, used in
stories and roofs like wall panels. The bearing system is specific considering the present
construction practice, which is why we used experimentally obtained mechanical properties of
KLH cyclically stressed timber structure systems capable of bearing the horizontal load. |
Keywords (ePrints, secondary language): |
timber structures;experimental research;experimentally supported modeling;seismic analysis;design case |
ID: |
8309600 |