diplomska naloga
Matic Šketa (Author), Dušan Kogoj (Mentor), Bojan Stopar (Thesis defence commission member), Božo Koler (Thesis defence commission member)

Abstract

Diplomska naloga obravnava testiranje sistema avtomatskega viziranja tahimetra Leica Geosystems TCRA1103 plus. Tahimeter omogoča avtomatsko viziranje tarč. Uvodni del opisuje razvoj in avtomatizacijo elektronskih tahimetrov. Posvetimo se tudi Leicinemu sistemu za avtomatsko prepoznavanje tarče ATR. Praktični del diplomske naloge obravnava testiranje natančnosti tahimetra Leica TCRA1103 plus pri merjenju horizontalnih smeri. Testirali smo natančnost sistema avtomatskega viziranja tarče ATR in jo primerjali z natančnostjo ročnega viziranja. Izvedli smo obsežna terenska merjenja. Natančnosti za posamezne meritve smo izračunali na osnovi enačb, zapisanih v standardu ISO 17123-3, in rezultate nato komentirali ter primerjali.

Keywords

geodezija;diplomska naloga;VSŠ;avtomatsko prepoznavanje tarče;avtomatsko viziranje;ATR;APT;AVT;AIT;AST;Leica TCRA1103 plus;primerjava natančnosti;ISO 17123-3;

Data

Language: Slovenian
Year of publishing:
Typology: 2.11 - Undergraduate Thesis
Organization: UL FGG - Faculty of Civil and Geodetic Engineering
Publisher: [M. Šketa]
UDC: 528.53(043.2)
COBISS: 6638945 Link will open in a new window
Views: 2014
Downloads: 505
Average score: 0 (0 votes)
Metadata: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Other data

Secondary language: English
Secondary title: Testing of the ATR system of Leica TCRA1103 plus total station
Secondary abstract: The aim of this paper is to test the automatic target recognition system of Leica TCRA1103 plus total station. A total station enables the automatic target recognition. The introductory part of my research is based on the development and automation of electronic total stations. Furthermore, the research is dedicated to the automatic target identifying system of Leica ATR. The aim of the practical part of this research is to test the accuracy of Leica TCRA1103 plus total station at horizontal directions measurement. The accuracy of the automatic target recognition ATR was tested and compared to the manual recognition accuracy. The extensive field measurements were carried out. The individual measurements’ accuracies were calculated on the basis of equations written in standard ISO 17123-3. The results were then commented and compared.
Secondary keywords: automatic target identifying;automatic recognition;ATR;APT;AVT;AIT;AST;Leica TCRA1103 plus;Accuracy comparison;ISO 17123-3;
File type: application/pdf
Type (COBISS): Undergraduate thesis
Thesis comment: Univ. v Ljubljani, Fak. za gradbeništvo in geodezijo
Pages: XII, 38 str., 2 pril.