diplomska naloga
Matic Šketa (Avtor), Dušan Kogoj (Mentor), Bojan Stopar (Član komisije za zagovor), Božo Koler (Član komisije za zagovor)

Povzetek

Diplomska naloga obravnava testiranje sistema avtomatskega viziranja tahimetra Leica Geosystems TCRA1103 plus. Tahimeter omogoča avtomatsko viziranje tarč. Uvodni del opisuje razvoj in avtomatizacijo elektronskih tahimetrov. Posvetimo se tudi Leicinemu sistemu za avtomatsko prepoznavanje tarče ATR. Praktični del diplomske naloge obravnava testiranje natančnosti tahimetra Leica TCRA1103 plus pri merjenju horizontalnih smeri. Testirali smo natančnost sistema avtomatskega viziranja tarče ATR in jo primerjali z natančnostjo ročnega viziranja. Izvedli smo obsežna terenska merjenja. Natančnosti za posamezne meritve smo izračunali na osnovi enačb, zapisanih v standardu ISO 17123-3, in rezultate nato komentirali ter primerjali.

Ključne besede

geodezija;diplomska naloga;VSŠ;avtomatsko prepoznavanje tarče;avtomatsko viziranje;ATR;APT;AVT;AIT;AST;Leica TCRA1103 plus;primerjava natančnosti;ISO 17123-3;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UL FGG - Fakulteta za gradbeništvo in geodezijo
Založnik: [M. Šketa]
UDK: 528.53(043.2)
COBISS: 6638945 Povezava se bo odprla v novem oknu
Št. ogledov: 2014
Št. prenosov: 505
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Testing of the ATR system of Leica TCRA1103 plus total station
Sekundarni povzetek: The aim of this paper is to test the automatic target recognition system of Leica TCRA1103 plus total station. A total station enables the automatic target recognition. The introductory part of my research is based on the development and automation of electronic total stations. Furthermore, the research is dedicated to the automatic target identifying system of Leica ATR. The aim of the practical part of this research is to test the accuracy of Leica TCRA1103 plus total station at horizontal directions measurement. The accuracy of the automatic target recognition ATR was tested and compared to the manual recognition accuracy. The extensive field measurements were carried out. The individual measurements’ accuracies were calculated on the basis of equations written in standard ISO 17123-3. The results were then commented and compared.
Sekundarne ključne besede: automatic target identifying;automatic recognition;ATR;APT;AVT;AIT;AST;Leica TCRA1103 plus;Accuracy comparison;ISO 17123-3;
Vrsta datoteke: application/pdf
Vrsta dela (COBISS): Diplomsko delo
Komentar na gradivo: Univ. v Ljubljani, Fak. za gradbeništvo in geodezijo
Strani: XII, 38 str., 2 pril.
ID: 8636180