diplomsko delo
Abstract
Namen diplomskega dela je validacija analizne metode za določevanje adsorbljivih organskih halogenov (AOX) v odpadnih vodah.
Proces validacije zajema določitev validacijskih parametrov z izdelavo validacijskega načrta. Sledi eksperimentalna izvedba validacije ter statistično pridobljenih rezultatov. Določili smo potrditev identitete in selektivnost oziroma specifičnost, delovno in linearno območje, mejo zaznavnosti, mejo določljivosti, LOQ v matrici, zgornjo mejo določanja v matrici, vpliv redčenja vzorcev, točnost, natančnost in vpliv matrice. Analizirani so bili tudi realni vzorci bazenskih, bolnišničnih odpadnih vod ter odpadne vode iz iztoka iz čistilnih naprav.
Na podlagi vseh pridobljenih rezultatov ter na predpisane parametre smo potrdili, da izbrana analizna metoda izpolnjuje predpisane pogoje ter zagotavlja pravilnost in zanesljivost rezultatov.
Keywords
AOX;validacija analizne metode;odpadne vode;adsorpcija;
Data
Language: |
Slovenian |
Year of publishing: |
2013 |
Typology: |
2.11 - Undergraduate Thesis |
Organization: |
UM FKKT - Faculty of Chemistry and Chemical Engineering |
Publisher: |
[N. Marot] |
UDC: |
543.2/.9:628.166(043.2) |
COBISS: |
17461014
|
Views: |
2043 |
Downloads: |
233 |
Average score: |
0 (0 votes) |
Metadata: |
|
Other data
Secondary language: |
English |
Secondary title: |
DETERMINATION OF ADSORBABLE ORGANICALLY BOUND HALOGENS IN WASTE WATERS |
Secondary abstract: |
The purpose of the this thesis was the validation of the analytical method for the determination of adsorbable organically bound halogens (AOX) in waste waters.
Validation process comprises determination of validation parameters and the validation plan. After the validation plan an experimental part of the validation with the statistically of results was performed.
We have also confirmed the identity and determined selectivity and specificity, working and linear range, limit of detection LOD, limit of quantitation, LOQ in the matrix, the upper limit of the matrix, the impact of dilution samples, accuracy, precision and matrix effect.
We also analysed real samples, a pool water, a hospital waste water and a waste water from effluent treatment plants.
On the basis of results obtained according to the prescribed parameters, it was confirmed that this analytical method complies with the conditions prescribed and ensures the accuracy and reliability of the results. |
Secondary keywords: |
AOX;validation of analytical methods;waste water;adsorption; |
URN: |
URN:SI:UM: |
Type (COBISS): |
Undergraduate thesis |
Thesis comment: |
Univ. v Mariboru, Fak. za kemijo in kemijsko tehnologijo |
Pages: |
78 f. |
ID: |
8725965 |