diplomsko delo visokošolskega strokovnega študijskega programa I. stopnje
Aljaž Ramot (Avtor), Matjaž Finšgar (Mentor), Barbara Petovar (Komentor)

Povzetek

The purpose of this thesis is to validate the electroanalytical method with an antimony electrode for trace metal analysis. The validation began with the determination of the limit of detection (LOD) and the limit of quantification (LOQ), proceeded with determining the method’s linearity and concluded with determination of accuracy and precision. The trace metal analysis was conducted via square-wave anodic stripping voltammetry (SWASV). Cyclic voltammetry (CV) was used to test the reversibility of the [Fe(CN)6] 3/[Fe(CN)6] 4 system. All the analyses were conducted in a 0.01 M HCl solution. The LOD and LOQ were not possible to report with certainty, since the method has such a low LOD that the contamination with heavy metals, even in ultrapure acid, was too high. The method had a linear response at deposition potentials of 1.2 V, 1.1 V and 1.0 V vs. Ag/AgCl for Pb(II) and Cd(II) from 14.6 µg L 1 to 100.0 µg L 1. It has further been proven that the method is accurate and precise for all three deposition potentials at 15 µg L 1, 25 µg L 1, 30 µg L 1, 40 µg L 1 concentrations of analytes. The results have shown that the method is best used at a deposition potential of 1.1 V vs. Ag/AgCl.

Ključne besede

heavy metal analysis;trace analysis;antimony electrode;voltammetry;SWASV;

Podatki

Jezik: Angleški jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UM FKKT - Fakulteta za kemijo in kemijsko tehnologijo
Založnik: [A. Ramot]
UDK: 543.55:549.25(043.2)
COBISS: 21059094 Povezava se bo odprla v novem oknu
Št. ogledov: 1213
Št. prenosov: 189
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Slovenski jezik
Sekundarni naslov: Validacija elektroanalizne metode z antimonovo elektrodo za analizo težkih kovin v sledovih
Sekundarni povzetek: Namen diplomskega dela je validacija elektroanalizne metode z antimonovo elektrodo za analizo težkih kovin v sledovih. Validacija se je pričela z določevanjem meje zaznavnosti (LOD) in meje kvantifikacije (LOQ), nadaljevala z določanjem linearnosti in končala z določanjem točnosti in natančnosti. Analiza težkih kovin je bila izvedena s square-wave anodno striping voltametrijo (SWASV), za testiranje reverzibilnosti sistema [Fe(CN)6] 3/[Fe(CN)6] 4 pa smo uporabili metodo ciklične voltametrije (CV). Vse analize so bile izvedene v 0,01 M raztopini HCl. Meje LOD in LOQ ni mogoče določiti z dovolj veliko gotovostjo, saj ima metoda tako nizko LOD, da je bila kontaminacija s težkimi kovinami, tudi v ultra čisti kislini, prevelika. Metoda ima linearen odziv pri potencialih depozicije 1,2 V, 1,1 V in 1,0 V vs. Ag/AgCl za Pb(II) in Cd(II) v območju od 14,6 µg L 1 do 100,0 µg L 1. Dokazano je tudi, da je metoda natančna in točna za vse tri potenciale depozicije pri koncentraciji analitov 15 µg L 1, 25 µg L 1, 30 µg L 1, 40 µg L 1. Ugotovljeno je bilo, da je metoda najbolj uporabna pri potencialu depozicije 1,1 V vs. Ag/AgCl.
Sekundarne ključne besede: analiza težkih kovin;analitika sledov;antimonova elektroda;voltametrija;diplomske naloge;
URN: URN:SI:UM:
Vrsta dela (COBISS): Diplomsko delo/naloga
Komentar na gradivo: Univ. v Mariboru, Fak. za kemijo in kemijsko tehnologijo
Strani: IX, 36 str.
ID: 10862132
Priporočena dela:
, diplomsko delo visokošolskega strokovnega študijskega programa I. stopnje
, diplomsko delo univerzitetnega študijskega programa I. stopnje
, diplomsko delo univerzitetnega študijskega programa I. stopnje
, diplomsko delo visokošolskega strokovnega študijskega programa I. stopnje