comparison of two sampling methods
Pouline M. van Oort (Avtor), I. R. White (Avtor), Waqar Ahmed (Avtor), Craig Johnson (Avtor), Jonathan Bannard-Smith (Avtor), Timothy Felton (Avtor), Lieuwe D. Bos (Avtor), Royston Goodacre (Avtor), Paul Dark (Avtor), Stephen J Fowler (Avtor)

Povzetek

Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We compared two breath sampling methods, first using an artificial ventilator circuit, then in “real life” in mechanically ventilated patients on the intensive care unit. In the laboratory circuit, a 24-component synthetic-breath volatile organic compound (VOC) mixture was injected into the system as air was sampled: (A) through a port on the exhalation limb of the circuit and (B) through a closed endo-bronchial suction catheter. Sorbent tubes were used to collect samples for analysis by thermal desorption-gas chromatography-mass spectrometry. Realistic mechanical ventilation rates and breath pressure–volume loops were established and method detection limits (MDLs) were calculated for all VOCs. Higher yields of VOCs were retrieved using the closed suction catheter; however, for several VOCs MDLs were compromised due to the background signal associated with plastic and rubber components in the catheters. Different brands of suction catheter were compared. Exhaled VOC data from 40 patient samples collected at two sites were then used to calculate the proportion of data analysed above the MDL. The relative performance of the two methods differed depending on the VOC under study and both methods showed sensitivity towards different exhaled VOCs. Furthermore, method performance differed depending on recruitment site, as the centres were equipped with different brands of respiratory equipment, an important consideration for the design of multicentre studies investigating exhaled VOCs in mechanically ventilated patients.

Ključne besede

volatile organic compounds;infection;breath;ventilator associated pneumonia;

Podatki

Jezik: Angleški jezik
Leto izida:
Tipologija: 1.01 - Izvirni znanstveni članek
Organizacija: UNG - Univerza v Novi Gorici
UDK: 611
COBISS: 42126339 Povezava se bo odprla v novem oknu
ISSN: 1364-5528
Št. ogledov: 1675
Št. prenosov: 0
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

URN: URN:SI:UNG
Vrsta dela (COBISS): Delo ni kategorizirano
Strani: str. 222-231
Letnik: ǂVol. ǂ146
Zvezek: ǂno. ǂ1
Čas izdaje: 2021
DOI: 10.1039/C9AN01134J
ID: 12241971
Priporočena dela:
, ǂa ǂbenchmarking protocol for breath sampling and analysis using GC-MS
, ǂa ǂglobal budget and source attribution