V uvodnem delu diplomske naloge so predstavljeni zakoni, ki omenjajo skoraj nič-energijsko stavbo. Na podlagi zahtev in omejitev teh zakonov je nato bila za poslovni objekt Šampionka, ki leži v okolici Nove Gorice, predlagana zasnova toplotnega ovoja in sistemov za ogrevanje, hlajenje in prezračevanje. Prav tako sem predlagal sistem za izkoriščanje obnovljivih virov energije. V prvem delu naloge sem izdelal tri fasadne pasove, ki se razlikujejo v debelini toplotne izolacije in tako tudi po faktorju toplotne prehodnosti. Izbral sem si tudi dve vrsti oken in tako imel na razpolago šest kombinacij toplotnega ovoja stavbe. Izračun toplotne prehodnosti stavbnega ovoja sem izdelal s programskim orodjem Ubakus. V drugem delu sem s programskim orodjem KI Energija izdelal energijsko analizo omenjene stavbe in rezultate primerjal z mejnimi vrednostmi iz Pravilnika o učinkoviti rabi energije v stavbah in Akcijskega načrta za skoraj nič-energijske stavbe. Za analizo sem si izbral tri različne sisteme ogrevanja, in sicer toplotno črpalko voda-voda, toplotno črpalko zemljina-voda in kondenzacijski kotel na plin ter tako lahko opazoval razlike med učinkovitostjo le-teh. Akcijski načrt za skoraj nič-energijske stavbe zahteva, da vsaj polovico vse porabljene energije v stavbi pridobimo iz obnovljivih virov na kraju samem ali v njegovi bližini. Izkaže se, da lahko tak delež dosežemo že z uporabo toplotne črpalke, ki izkorišča aerotermalno energijo okolja. Pri ogrevanju s kondenzacijskim kotlom na plin tega deleža seveda ne dosežemo. Za stavbo je bila tako načrtovana vgradnja fotovoltaičnega sistema s katerim lahko dosežemo zahtevan delež. Elektriko, ki je ne porabimo za ogrevanje, lahko nato porabljamo za razsvetljavo ali napajanje raznih električnih naprav znotraj objekta.
Ključne besede
gradbeništvo;diplomske naloge;UNI;GR;B-GR;skoraj nič-energijska stavba;direktiva EPBD;PURES 2010;energijska učinkovitost;obnovljivi viri energije;
Podatki
Jezik: |
Slovenski jezik |
Leto izida: |
2021 |
Tipologija: |
2.11 - Diplomsko delo |
Organizacija: |
UL FGG - Fakulteta za gradbeništvo in geodezijo |
Založnik: |
[T. Leban] |
UDK: |
502.174.3:620.9:728(043.2) |
COBISS: |
67558147
|
Št. ogledov: |
484 |
Št. prenosov: |
123 |
Ocena: |
0 (0 glasov) |
Metapodatki: |
|
Ostali podatki
Sekundarni jezik: |
Angleški jezik |
Sekundarni naslov: |
Analysis of measures to achieve a near zero-energy building at the Šampionka business facility |
Sekundarni povzetek: |
In the first part, the thesis presents legislation that mention a near zero-energy building. Based on the requirements and restrictions of these legislations, I proposed the design of the thermal envelope as well as heating, cooling, and ventilation systems for the Šampionka business facility, located in the vicinity of Nova Gorica. I also proposed a system for the exploitation of renewable energy sources. In the first part of the thesis, I designed three facade sections, which differ in their insulation thickness, thus have different thermal transmittance factors. Since I chose two different types of windows, I had six combinations of thermal envelopes of the building. I conducted calculations of the thermal transmittance of the building envelope with the software tool called Ubakus. In the second part, I did an energy analysis of the mentioned building with the software tool KI Energija and compared the results with the limit values obtained from PURES 2010 and AN sNES. For the analysis, I chose three different heating systems: a water-water heat pump, a ground-water heat pump and a gas-fired condensing boiler, in order to assess the differences between their efficiencies. AN sNES requires that at least half of all the energy consumed in a building is derived from renewable sources on-site or near the site. It turns out that such a share can be achieved by employing a heat pump, which uses aerothermal energy. Such an energy share could not be achieved when heating with a gas condensing boiler. The installation of a photovoltaic system was planned on the building, so that the required share could be achieved. Electricity that was not used for heating, can then be used for illumination or for powering various electrical devices inside the building. |
Sekundarne ključne besede: |
civil engineering;graduation thesis;near zero-energy house;directive EPBD;PURES 2010;energy efficiency;costsenergy efficiency,; |
Vrsta dela (COBISS): |
Diplomsko delo/naloga |
Študijski program: |
0 |
Konec prepovedi (OpenAIRE): |
1970-01-01 |
Komentar na gradivo: |
Univ. v Ljubljani, Fak. za gradbeništvo in geodezijo |
Strani: |
XI, 46 str. |
ID: |
12515747 |