Nina Čelofiga (Avtor), Urška Puh (Avtor)

Povzetek

Test devetih zatičev je eno najpogosteje uporabljenih merilnih orodij za oceno spretnosti roke, tudi pri pacientih z multiplo sklerozo in po možganski kapi, vendar pa se postopki izvedbe testa in načini poročanja izidov razlikujejo. Namen pregleda literature je bil povzeti merske lastnosti testa devetih zatičev pri teh dveh populacijah pacientov ter pripraviti navodila za poenotenje izvedbe testa. Metode: Pregled literature je potekal v PubMed in CINAHL ter zajel raziskave o merskih lastnostih, ki so ustrezale merilom za vključitev. Rezultati: V pregled smo vključili deset raziskav. Za test devetih zatičev je bila pri obeh populacijah ugotovljena visoka do odlična zanesljivost posameznega preiskovalca. Zanesljivost med preiskovalci pri pacientih z multiplo sklerozo je bila odlična, po možganski kapi je niso proučevali. Povezanost testa je bila višja s funkcijskimi testi za oceno dejavnosti kot merilnimi orodji telesnih funkcij. Občutljivost testa devetih zatičev je bila zmanjšana pri preiskovancih s spastičnostjo. Zaključek: Test devetih zatičev je veljavno in zanesljivo merilno orodje za oceno spretnosti roke pri pacientih z multiplo sklerozo ali po možganski kapi. Prevedli smo standardna navodila za izvedbo testa, ki smo jih dopolnili s prilagoditvami za preiskovance, ki ne zmorejo opraviti testne naloge v celoti.

Ključne besede

test devetih zatičev;veljavnost;zanesljivost;merske lastnosti;navodila;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 1.02 - Pregledni znanstveni članek
Organizacija: UL ZF - Zdravstvena fakulteta
UDK: 615.8
COBISS: 70774531 Povezava se bo odprla v novem oknu
ISSN: 1318-2102
Št. ogledov: 139
Št. prenosov: 21
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Measurement properties of the nine hole peg test in patients with multiple sclerosis and patients after stroke
Sekundarni povzetek: The Nine Hole Peg Test (9-HPT) is one of the most commonly used measurement tools to assess fine motor skills of the hand, including patients with multiple sclerosis and patients after stroke. However, there is a variation in the test protocols. The purpose of the literature review was to summarize the measurement properties of the 9-HPT in both populations and to prepare standardized instructions. Methods: The literature review was conducted in databases PubMed and CINAHL. The included studies of the 9-HPT measurement properties had to meet the inclusion criteria. Results: Ten studies were included in the review. Intra-rater reliability of the 9-HPT in both populations was high to excellent. Inter-rater reliability in patients with multiple sclerosis was excellent, it was not studied in patients after stroke. Concurrent validity of the 9-HPT was greater with measures of activity than body functions. Intra-rater reliability and sensitivity were decreased in patients with spasticity. Conclusion: The 9- HPT is a valid and reliable measure of fine motor skills in patients with multiple sclerosis or after stroke. We translated the standardized instructions, which we supplemented with adjustments for patients, who are unable to fully complete the task.
Sekundarne ključne besede: nine hole peg test;validity;reliability;measurement properties;protocol;
Vrsta dela (COBISS): Članek v reviji
Strani: str. 35-44
Letnik: ǂLetn. ǂ29
Zvezek: ǂšt. ǂ1
Čas izdaje: 2021
ID: 14229719