Povzetek

The number of harmful cyanobacterial blooms has increased significantly at the global level in recent years. One of the characteristics of cyanobacteria that gives them advantage over other phytoplankton organisms are auxiliary photosynthetic pigments, such as phycocyanin. This fluorescent pigment emits light at a different wavelength as chlorophyll and can therefore be used for detection of cyanobacteria in situ. In this study we used submersible phycocyanin fluorescence sensors and compare their voltage output to concentration of extracted phycocyanin, cell counts and biovolume. The relation was linear in all three cases; however, the variability of regression line slopes between different cyanobacteria strains was high in the case of PC extract concentration and cell count. The highest uniformity in the linear fits was between fluorescence signal and biovolume therefore making it the best candidate for fluorescence sensor voltage output conversion. In the context of this work we also compared different methods for PC extraction. Modifying the equations by subtracting the absorption at 750 nm almost entirely reduces the false PC concentration estimation due to sample turbidity.

Ključne besede

fluorescence measurements;phycocyanin;cyanobacteria;

Podatki

Jezik: Angleški jezik
Leto izida:
Tipologija: 1.01 - Izvirni znanstveni članek
Organizacija: UL BF - Biotehniška fakulteta
UDK: 581
COBISS: 4556111 Povezava se bo odprla v novem oknu
ISSN: 1408-3671
Št. ogledov: 42
Št. prenosov: 14
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Slovenski jezik
Sekundarni naslov: Vrednotenje biomase cianobakterij na osnovi nadgradnje ocene fluorescence fikocianina
Sekundarni povzetek: V zadnjih letih se število škodljivih cvetenj cianobakterij na globalni ravni močno povečuje. Ena od značilnosti cianobakterij, ki jim prinaša prednost pred ostalimi fitoplanktonskimi organizmi, so pomožna fotosintezna barvila, med katerimi prevladuje fikocianin. Fikocianin fluorescira pri drugi valovni dolžini kot klorofil, zato lahko s pomočjo meritve fluorescence ugotavljamo prisotnost cianobakterij v vodnem okolju in situ. S potopnim senzorjem fluorescence fikocianina smo opravili meritve dveh sojev cianobakterije Microcystis aeruginosa in nitaste cianobakterije vrste Arthrospira platensis. Odnos med koncentracijo ekstrahiranega fikocianina, številom celic in njihovim biovolumnom ter fluorescenco fikocianina je bil v vseh treh primerih linearen, vendar pa je bila variabilnost naklonov regresijske premice v primeru koncentracije fikocianinskega ekstrakta in števila celic med različnimi vrstami cianobakterij visoka. Najvišje ujemanje naklonov linearnih regresij je bilo med signa-lom senzorja in biovolumnom, zaradi česar je najboljši kandidat za pretvorbo izhodne napetosti fluorescenčnega senzorja v limnološko pomembno količino. V okviru tega dela smo primerjali tudi različne protokole za ekstrakcijo fikocianina. Obstoječe enačbe za pretvarjanje absorpcije v koncentracijo fikocianina smo dopolnili z odštevanjem absorpcije vzorca pri 750 nm in s tem zmanjšali zavajujočo oceno koncentracije.
Sekundarne ključne besede: meritve fluorescence;fikocianin;cianobakterije;
Komentar vira: Besedilo v angl.;
Strani: str. 21-28
Letnik: ǂVol. ǂ60
Zvezek: ǂšt. ǂ2
Čas izdaje: 2017
ID: 24637911