Povzetek
The corrosion behavior of dissimilar weldments between AISI310 and AISI2205 stainless steels in a 5 % calcium chloride solution at 50 °C was investigated under three conditions: as-welded, lower post-weld heat treatment at 800 °C, and higher post-weld heat treatment at 1000 °C. Microstructural examination revealed severe pitting in the as-welded sample, with pit widths ranging from 270 μm to 360 μm. The lower heat-treated sample had larger pits (310 μm to 370 μm), while the higher heat-treated sample showed homogeneous corrosion with a protective oxide coating. The as-welded sample had the highest corrosion rate, followed by the lower heat-treated sample, which had a moderate rate, and the higher heat-treated sample had the lowest rate. The corrosion current densities were 5,26 × ▫$10^{-3}$▫ mA/cm², 4,6 × ▫$10^{-4}$▫ mA/cm² and 1,4 × ▫$10^{-4}$▫ mA/cm², respectively. Electrochemical noise measurements confirmed these findings, with the higher heat-treated sample showing negligible localized corrosion and homogenous corrosion behavior.
Ključne besede
AISI2205;corrosion;electrochemical impedance spectroscopy;Ca▫$Cl_2$▫;
Podatki
Jezik: |
Angleški jezik |
Leto izida: |
2025 |
Tipologija: |
1.01 - Izvirni znanstveni članek |
Organizacija: |
UL FS - Fakulteta za strojništvo |
UDK: |
621 |
COBISS: |
227927811
|
ISSN: |
2536-3948 |
Št. ogledov: |
22 |
Št. prenosov: |
0 |
Ocena: |
0 (0 glasov) |
Metapodatki: |
|
Ostali podatki
Sekundarni jezik: |
Slovenski jezik |
Sekundarni povzetek: |
Korozijsko obnašanje neenakih zvarov nerjavnih jekel AISI310 in AISI2205v 5-odstotni raztopini kalcijevega klorida pri 50 °C je bilo raziskano pod tremi pogoji: kot varjeno, z nižjo toplotno obdelavo po varjenju pri 800 °C in z višjo toplotno obdelavo po varjenju pri 1000 °C. Mikrostrukturna analiza je pokazala izrazito jamasto korozijopri varjenem vzorcu, pri čemer so bile širine jamic med 270 μm in 360 μm. Vzorec z nižjo toplotno obdelavo je imel večje vdolbine (310 μm do 370 μm), medtem ko je pri vzorcu, ki je bil toplotno obdelan višje, opaziti homogeno korozijo z zaščitno oksidno prevleko. Najvišjo stopnjo korozije je imel varjeni vzorec, sledil mu je nizko- toplotno obdelani vzorec z zmerno stopnjo, najnižjo stopnjo korozije pa je imel visoko-toplotno obdelani vzorec. Gostote korozijskega toka so bile 5,26 × ▫$10^{-3}$▫ mA/cm², 4,6 × ▫$10^{-4}$▫ mA/cm² oziroma 1,4 × ▫$10^{-4}$▫ mA/cm². Elektrokemične meritve šuma so potrdile te ugotovitve, pri čemer je vzorec, ki je bil obdelan z višjo toplotno obdelavo, pokazal zanemarljivo lokalizirano korozijo in homogeno korozijsko obnašanje. |
Strani: |
str. 3-9 |
Letnik: |
ǂVol. ǂ71 |
Zvezek: |
ǂno. ǂ1/2 |
Čas izdaje: |
2025 |
DOI: |
10.5545/sv-jme.2024.1084 |
ID: |
26010936 |