diplomska naloga
Rožle Pavlin (Avtor), Sebastjan Bratina (Mentor), Janko Logar (Član komisije za zagovor), Tatjana Isaković (Član komisije za zagovor)

Povzetek

V diplomski nalogi analiziramo in projektiramo nosilno konstrukcijo upravne stavbe CGP po trenutno veljavnih standardih na področju gradbenih konstrukcij Evrokod. Nosilna konstrukcija stavbe je iz armiranega betona in je sestavljena iz dveh delov, ki sta medsebojno ločena z dilatacijo. Osredotočimo se na novejši del, ki je bil zgrajen leta 2007 in ima pet etaž, poleg kleti in pritličja še dve nadstropji ter podstrešje. Nosilno konstrukcijo sestavljajo monolitne armiranobetonske stropne plošče ter armiranobetonske stene, ki so med seboj povezane s prečkami. Analizo stropnih plošč smo izvedli s pomočjo komercialnega programa SAFE, analizo vertikalnih nosilnih elementov pa s programom ETABS. Pri analizi smo upoštevali stalne vplive, koristne vplive, obtežbo snega in vetra ter potresni vpliv. Natančneje prikazujemo projektiranje tipične stropne konstrukcije, najbolj obremenjene konzolne stene ter stene in prečke iz sistema povezanih sten. Obravnavani vertikalni nosilni elementi so projektirani po metodi načrtovanja nosilnosti. V analizi primerjamo potrebno količino armature, ki jo zahtevajo standardi Evrokod, in količino armature, ki je dejansko vgrajena v obravnavane nosilne elemente stavbe. Obravnavana stavba je bila analizirana oziroma projektirana po starih jugoslovanskih predpisih (JUS). S primerjavo smo ugotovili, da je bila razlika v armaturi stropne konstrukcije predvsem posledica natančnejšega računskega modela, ki smo ga uporabili v diplomski nalogi, ne pa različnih zahtev iz predpisov. Pri projektiranju sten je največja razlika v upoštevani dolžini robnih elementov, kjer zgoščamo navpično armaturo. Evrokod zahteva daljše robne elemente kot so dejansko izvedeni, v stojini stene pa občutno manjšo količino armature. V prečkah, ki povezujejo stene, so razlike med količino dejansko vgrajene armature in potrebne armature po Evrokodu majhne. Stremenske armature je po količini dovolj, le razdalja med posameznimi zankami je prevelika. Razporeditev armature v obravnavanih nosilnih elementih, skladno z zahtevami Evrokoda, prikazujemo v armaturnih načrtih.

Ključne besede

gradbeništvo;diplomska dela;UNI;standard Evrokod;plošče;stene;armiran beton;projektiranje;upravne stavbe;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UL FGG - Fakulteta za gradbeništvo in geodezijo
Založnik: [R. Pavlin]
UDK: 006:624.012.45(043.2)
COBISS: 5841505 Povezava se bo odprla v novem oknu
Št. ogledov: 3446
Št. prenosov: 1300
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Design of CGP administrative building according to Eurocode standards
Sekundarni povzetek: This thesis presents the designing of the administrative building of CGP according to the current Eurocode standards in the field of constructions. Reinforced concrete construction consists of two parts which are separated with dilatation. The focus is on the part of the building that was built in 2007 and consists of the basement, the ground floor, two floors and the attic. The load-bearing construction of this five-storey building consists of monolith reinforced concrete plates and walls of reinforced concrete which are connected with beams. The analysis of vertical load-bearing elements was made with the use of the ETABS program, while the analysis of ceiling plates was performed with the SAFE program. In the analysis, permanent impacts, impacts of imposed loads, snow and wind loads, but also seismic effects were taken into consideration. Presented in detail is the designing of characteristic ceiling construction, the most loaded cantilever wall, and the wall and the beam from the system of connected walls. The presented vertical load-bearing elements are designed by the method of capacity design. The purpose of analysing an already built structure is to compare the quantity of reinforcement required by Eurocode standards with the actual reinforcement, established in accordance with the requirements of the Yugoslav regulations (JUS). The comparison indicated that a more accurate model used in this thesis has a greater effect on the quantity of reinforcement in ceiling construction than the difference in regulations. Nevertheless, the Eurocode standard requires longer boundary elements and significantly less reinforcement in the web of the wall. In beams that connect the walls, there are small differences between the quantities of built-in reinforcement and the reinforcement required by the Eurocode standard. Shear reinforcement is sufficient, only the distance between the bars is too big. The amounts and locations of reinforcement in analysed elements are shown in the reinforcement drawing.
Sekundarne ključne besede: graduation thesis;civil engineering;Eurocode standards;plates;walls;reinforced concrete;design;administrative buildings;
Vrsta datoteke: application/pdf
Vrsta dela (COBISS): Diplomsko delo
Komentar na gradivo: Univ. v Ljubljani, Fak. za gradbeništvo in geodezijo
Strani: XIV, 99 str., [10] str. pril.