Povzetek

Na tržišču je ogromno proizvajalcev geodetske opreme, ki trdijo, da je njihov izdelek tako točen, kot to navajajo. V sklopu te diplomske naloge smo preverili adicijsko konstanto treh mini reflektorjev GMP 111 in ali ta odgovarja navedbam proizvajalca. V diplomski nalogi so predstavljeni elektronski razdaljemeri in reflektorji. Obravnavani so tudi pogreški, ki vplivajo na kakovost izvedenih meritev. Bistvo diplomske naloge je analiza adicijske konstante. Izmero smo izvedli v zaprtem prostoru in na prostem. Naredili smo tri serije meritev za posamezno prizmo na treh različnih dolžinah in dobili rezultate. Te rezultate smo primerjali z navedbami proizvajalca in jih analizirali v zaključku.

Ključne besede

geodezija;diplomska naloga;VSŠ;adicijska konstanta;mini prizma;instrument;

Podatki

Jezik: Slovenski jezik
Leto izida:
Tipologija: 2.11 - Diplomsko delo
Organizacija: UL FGG - Fakulteta za gradbeništvo in geodezijo
Založnik: [M. Tomšič]
UDK: 528.5:681.783.2(497.4)(043.2)
COBISS: 7537761 Povezava se bo odprla v novem oknu
Št. ogledov: 2762
Št. prenosov: 391
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarni naslov: Determination of the addition constants mini prism GPM 111
Sekundarni povzetek: The market is full of geodesic equipment manufacturers, each with various claims as to the accuracy of their products. In the scope of this thesis, we have measured the addition constant of three GMP 111 mini prisms, and examined how accurate the manufacturer's claims are. The thesis also presents electronic distance measurers and reflectors. Various different errors, which affected the quality of the measurements, are detailed in the thesis. Its core consists of the analysis of the addition constant. The measurements were done both indoors and outdoors. We made three series of measurements for each prism over three different distances; those were the source of my results. These were then compared with the manufacturer's claims and were analysed in the conclusion.
Sekundarne ključne besede: geodesy;graduation thesis;addition constant;mini prism;instrument;