(diplomsko delo)
Povzetek
V diplomskem delu, smo raziskovali kakšna je vsebina reanimacijskih vozičkov v naših zdravstvenih ustanovah. Ugotavljamo, da obstajajo standardi glede vsebine medicinskega materiala, opreme in zdravil, ni pa standarda zlaganja medicinskega materiala, opreme in zdravil v reanimacijskem vozičku. Ker ti standardi točnih lokacij medicinskih pripomočkov ne obstajajo, je lahko pričakovati daljši dostopni čas do opreme. Predstavili smo Broselow trak, kot pripomoček pri reanimaciji otrok in z njim povezan sistem kodiranja reanimacijskih vozičkov po Broselow-Luten sistemu, ki se v tujini že uveljavlja. Ugotavljamo, da pri nas še ni prakse za kodiranje reanimacijskih vozičkov po Broselow-Luten sistemu, sam Broselow trak pa se redko uporablja.
Ključne besede
reanimacijski voziček;Broselow trak;Broselow-Luten barvno kodiranje;
Podatki
Jezik: |
Slovenski jezik |
Leto izida: |
2011 |
Izvor: |
Maribor |
Tipologija: |
2.11 - Diplomsko delo |
Organizacija: |
UM MF - Medicinska fakulteta |
Založnik: |
[A. Ačko] |
UDK: |
615.4 |
COBISS: |
1763492
|
Št. ogledov: |
2650 |
Št. prenosov: |
838 |
Ocena: |
0 (0 glasov) |
Metapodatki: |
|
Ostali podatki
Sekundarni jezik: |
Angleški jezik |
Sekundarni naslov: |
The Broselow-Luten system of coding in a crash cart |
Sekundarni povzetek: |
In the following paper we investigated the contents of reanimation carts in our medical facilities. Our conclusion is that there are standards for medical materials, equipment and medication that are stored in them, but there is no regulation that defines how they are placed in the carts. And because there is no placement regulation, a certain object may take longer to be found in the cart. We present Broselow tape as an instrument in children's reanimation and it's connection to the coding system of reanimation carts based on the Broselow-Luten system, that is already put into effect in some countries abroad. Our conclusion is that reanimation carts are still not being coded with the use of Bruselow-Luten system in our medical facilities and the usage of Broselow tape is very seldom. |
Sekundarne ključne besede: |
resuscitation cart;Broselow tape;Broselow-Luten color coding.; |
URN: |
URN:SI:UM: |
Vrsta dela (COBISS): |
Diplomsko delo |
Komentar na gradivo: |
Univ. v Mariboru, Fak. za zdravstvene vede |
Strani: |
V, 60 f., 5 f. pril. |
Ključne besede (UDK): |
applied sciences;medicine;technology;uporabne znanosti;medicina;tehnika;medical sciences;medicina;pharmacology;therapeutics;toxicology;farmakologija;terapevtika;toksikologija;pharmaceutical preparations;medical material;equipment;farmacevtski pripravki;medicinski materiali;oprema; |
ID: |
15366 |