Povzetek

Research results of how the precipitated water scale on heaters of small domestic appliances influences the consumption of electricity are presented. It shows that the majority of water scale samples are composed of aragonite, calcite and dolomite and that those components have an extraordinary low thermal conductivity. Also, the results show that at 2 mm thick deposit, depending on the chemical composition of water scale, the thermal flow is reduced for 10% to 40%; consequently, the consumption of electricity significantly increases.

Ključne besede

elektriciteta;prenos toplote;toplotni izmenjevalci;vodni kamen;usedline;preprečevanje vodnega kamna;električni grelec;electricity;heat transfer;heat flow;heat exchanger;water scale;

Podatki

Jezik: Angleški jezik
Leto izida:
Tipologija: 1.01 - Izvirni znanstveni članek
Organizacija: UM FKKT - Fakulteta za kemijo in kemijsko tehnologijo
UDK: 628.162:537.84
COBISS: 12315670 Povezava se bo odprla v novem oknu
ISSN: Y506-2152
Št. ogledov: 1699
Št. prenosov: 54
Ocena: 0 (0 glasov)
Metapodatki: JSON JSON-RDF JSON-LD TURTLE N-TRIPLES XML RDFA MICRODATA DC-XML DC-RDF RDF

Ostali podatki

Sekundarni jezik: Angleški jezik
Sekundarne ključne besede: elektriciteta;prenos toplote;toplotni izmenjevalci;vodni kamen;usedline;preprečevanje vodnega kamna;električni grelec;
URN: URN:SI:UM:
Strani: str. 55-61
Letnik: ǂVol. ǂ1
Zvezek: ǂno. ǂ2
Čas izdaje: 2007
ID: 8717220
Priporočena dela:
, diplomska naloga visokošolskega strokovnega študijskega programa
, diplomska naloga visokošolskega študijskega programa